Home-based overnight transcutaneous capnography/pulse oximetry for diagnosing nocturnal hypoventilation associated with neuromuscular disorders.
Arch Phys Med Rehabil
; 94(1): 46-52, 2013 Jan.
Article
em En
| MEDLINE
| ID: mdl-22964272
OBJECTIVE: To determine the utility of home-based, unsupervised transcutaneous partial pressure of carbon dioxide (tc-Pco(2)) monitoring/oxygen saturation by pulse oximetry (Spo(2)) for detecting nocturnal hypoventilation (NH) in individuals with neuromuscular disorders. DESIGN: Retrospective case series analyzed consecutively. SETTING: Multidisciplinary neuromuscular respiratory failure (NMRF) clinic at an academic institution. PARTICIPANTS: Subjects (N=35, 68.6% men; mean age, 46.9y) with spinal cord injury (45.7%) or other neuromuscular disorders underwent overnight tests with tc-Pco(2)/Spo(2) monitoring. Fifteen (42.9%) were using nocturnal ventilatory support, either bilevel positive airway pressure (BiPAP) or tracheostomy ventilation (TV). INTERVENTIONS: A respiratory therapist brought a calibrated tc-Pco(2)/Spo(2) monitor to the patient's home and provided instructions for data collection during the subject's normal sleep period. Forced vital capacity (FVC), body mass index (BMI), and exhaled end-tidal Pco(2) (ET-Pco(2)) were recorded at a clinic visit before monitoring. MAIN OUTCOME MEASURES: Detection of NH (tc-Pco(2) ≥50mmHg for ≥5% of monitoring time). Data were also analyzed to determine whether nocturnal oxygen desaturation (Spo(2) ≤88% for ≥5% of monitoring time), FVC, BMI, or daytime ET-Pco(2) could predict the presence of NH. RESULTS: NH was detected in 18 subjects (51.4%), including 53.3% of those using BiPAP or TV. NH was detected in 43.8% of ventilator-independent subjects with normal daytime ET-Pco(2) (present for 49.4%±31.5% [mean ± SD] of the study period), and in 75% of subjects with an elevated daytime ET-Pco(2) (present for 92.3%±8.7% of the study period). Oxygen desaturation, BMI, and FVC were poor predictors of NH. Only 3 attempted monitoring studies failed to produce acceptable results. CONCLUSIONS: Home-based, unsupervised monitoring with tc-Pco(2)/Spo(2) is a useful method for diagnosing NH in NMRF.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Oximetria
/
Monitorização Ambulatorial
/
Capnografia
/
Hipoventilação
/
Doenças Neuromusculares
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Arch Phys Med Rehabil
Ano de publicação:
2013
Tipo de documento:
Article