Your browser doesn't support javascript.
loading
Resynchronization improves heart-arterial coupling reducing arterial load determinants.
Zócalo, Yanina; Bia, Daniel; Armentano, Ricardo L; González-Moreno, Juan; Varela, Gonzalo; Calleriza, Fernando; Reyes-Caorsi, Walter.
Afiliação
  • Zócalo Y; Physiology Department, Centro Universitario de Investigación, Innovación y Diagnóstico Arterial (CUiiDARTE), School of Medicine, Universidad de la República, General Flores 2125, Montevideo PC: 11800, República Oriental del Uruguay. yana@fmed.edu.uy
Europace ; 15(4): 554-65, 2013 Apr.
Article em En | MEDLINE | ID: mdl-23143859
BACKGROUND: Cardiac resynchronization therapy (CRT) has benefits on left ventricle (LV) performance, but its mid-term effects on LV load and LV-arterial coupling are unknown. AIMS: To evaluate CRT mid-term effects on LV-arterial coupling, arterial load and its determinants, and the association between CRT-dependent aortic haemodynamic changes and the arterial biomechanics. METHODS AND RESULTS: Cardiac and aortic echographies were done in 25 patients (age: 61 ± 12 years; 14 men; New York Heart Association functional classes III-IV; LV ejection fraction = 28 ± 7%, QRS = 139 ± 20 ms) before and after (23 ± 12 days) CRT. Standard structural and functional parameters and dyssynchrony indices were evaluated. Ascending aorta flow and diameter waveforms were measured. Central pressure was derived using a transfer function and the diameter calibration method. Calculus: arterial elastance (EA); aortic impedance (Zc) and distensibility (AD); systemic resistances (SVR), total compliance (CT); global reflection coefficient; LV end-systolic elastance (EES); and LV-arterial coupling (EA/EES). After CRT EA diminished (-30%;P = 0.001), EES increased (29%; P = 0.001) and EA/EES improved (pre-CRT: 2.9 ± 0.9, post-CRT: 1.6 ± 0.7; P = 0.001). Arterial elastance changes were associated with changes in arterial properties. Cardiac resynchronization therapy was associated with pressure-independent increase in mean aortic diameter (pre-CRT: 30.0 ± 4.0 mm, post-CRT: 33.0 ± 5.1 mm; P = 0.005) and distensibility (pre-CRT: 3.8 ± 2.6 × 10(-3)mmHg(-1), post-CRT: 6.4 ± 2.5 × 10(-3) mmHg(-1); P = 0.002), and Zc reduction (pre-CRT: 3.5 ± 1.8 × 10(-2)mmHg.s/mL, post-CRT:1.9 ± 0.8 × 10(-2) mmHg.s/mL; P = 0.001) and SVR (pre-CRT:1.7 ± 0.4 mmHg.s/mL, post-CRT:1.0 ± 0.3 mmHg.s/mL; P = 0.001). Changes in EA determinants were associated with changes in aortic flow. CONCLUSION: Early after CRT central and peripheral arterial biomechanics improved, determining a pressure-independent increase in aortic diameter and a reduction in arterial load. Left ventricular systolic performance and LV-arterial coupling were enhanced. Arterial biomechanical changes were associated with aortic flow changes.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta / Função Ventricular Esquerda / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Hemodinâmica Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta / Função Ventricular Esquerda / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Hemodinâmica Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2013 Tipo de documento: Article