Fibrin sealants or cell saver eliminate the need for autologous blood donation in anemic patients undergoing primary total knee arthroplasty.
Bou Monsef, Jad; Buckup, Johannes; Waldstein, Wenzel; Cornell, Charles; Boettner, Friedrich.
Afiliação
  • Bou Monsef J; Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Arch Orthop Trauma Surg ; 134(1): 53-8, 2014 Jan.
Article em En | MEDLINE | ID: mdl-24190654
INTRODUCTION: Reducing allogeneic blood transfusions remains a challenge in total knee arthroplasty. Patients with preoperative anemia have a particularly high risk for perioperative blood transfusions. MATERIALS AND METHODS: 176 anemic patients (Hb < 13.5 g/dl) undergoing total knee replacement were prospectively evaluated to compare the effect of a perioperative cell saver (26 patients), intraoperative fibrin sealants (5 ml Evicel, Johnson & Johnson Wound Management, Ethicon, Somerville, NJ) (45 patients), preoperative autologous blood donation (PABD) (21 patients), the combination of fibrin sealants and preoperative autologous blood donation (44) and no intervention (40 patients) on perioperative blood loss and transfusion requirements. RESULTS: All protocols resulted in significant reduction of allogeneic blood transfusions. Transfusion rates were similar with the use of PABD (19%), Evicel (18%), and cell saver (19%), all significantly lower than the control group (38 %, p < 0.05). Combining Evicel with PABD resulted in significantly higher wastage of autologous units (p < 0.05) with no significant reduction in allogeneic transfusion rate (14%). The use of fibrin sealant resulted in a significant reduction of blood loss compared to the PABD group (603 vs. 810 ml, p < 0.005) as well as the control group (603 vs. 822 ml, p < 0.005). CONCLUSIONS: While PABD proved to be the most cost-effective treatment option in anemic patients, fibrin sealants and cell saver show similar reduction in allogeneic transfusion rates compared to controls. The combination of fibrin sealants and PABD is not cost-effective and increases the number of wasted units.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transfusão de Sangue Autóloga / Adesivo Tecidual de Fibrina / Perda Sanguínea Cirúrgica / Hemorragia Pós-Operatória / Artroplastia do Joelho / Anemia Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transfusão de Sangue Autóloga / Adesivo Tecidual de Fibrina / Perda Sanguínea Cirúrgica / Hemorragia Pós-Operatória / Artroplastia do Joelho / Anemia Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos