Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography.
Tada, Tomohisa; Kastrati, Adnan; Byrne, Robert A; Schuster, Tibor; Cuni, Rezarta; King, Lamin A; Cassese, Salvatore; Joner, Michael; Pache, Jürgen; Massberg, Steffen; Schömig, Albert; Mehilli, Julinda.
Afiliação
  • Tada T; Deutsches Herzzentrum, Technische Universität, Lazarettstrasse 36, 80636, Munich, Germany, tomohisa@kuhp.kyoto-u.ac.jp.
Int J Cardiovasc Imaging ; 30(3): 495-504, 2014 Mar.
Article em En | MEDLINE | ID: mdl-24452729
ABSTRACT
We sought to compare the healing patterns of biolimus-eluting stents with biodegradable polymer (BP-BES, Nobori) versus everolimus-eluting stents with permanent polymer (PP-EES, Xience) using intravascular optical coherence tomography (OCT). A total of 34 patients undergoing treatment of de novo coronary lesions were randomly assigned to receive BP-BES (n = 15) or PP-EES (n = 19). Stent tissue coverage and apposition as well as the incidence of peri-strut low intensity area (PLIA) were assessed by OCT at 6-8 months. Generalized linear mixed models were used to account for clustered data. OCT imaging was available for 17 lesions with 2,805 struts in the BP-BES group and 22 lesions with 3,890 struts in the PP-EES group. BP-BES as compared to PP-EES showed similar rates of uncovered struts (479 vs. 588, odds ratio (OR) 1.54 (95 % CI 0.63-3.79), P = 0.34) and malapposed struts (46 vs. 32 struts, OR 1.64 [95 % CI 0.21-12.5], P = 0.64). Three lesions with BP-BES (17.6 %) versus 5 lesions with PP-EES (22.7 %) had >30 % uncovered struts (P = 0.78). The proportion of patients with PLIA was similar in both groups (BP-BES 41.2 % vs. PP-EES 36.4 %, OR 1.11 [95 % CI 0.43-2.87], P = 0.83). New generation BP-BES as compared to PP-EES showed similar stent coverage and apposition as assessed by OCT at 6-8 months. In addition, PLIA-possible markers of delayed arterial healing-were observed with similar frequency in both groups.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Teste de Materiais / Sirolimo / Materiais Revestidos Biocompatíveis / Tomografia de Coerência Óptica / Stents Farmacológicos Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Teste de Materiais / Sirolimo / Materiais Revestidos Biocompatíveis / Tomografia de Coerência Óptica / Stents Farmacológicos Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2014 Tipo de documento: Article