Your browser doesn't support javascript.
loading
Intraoperative radiological margin assessment in breast-conserving surgery.
Ihrai, T; Quaranta, D; Fouche, Y; Machiavello, J-C; Raoust, I; Chapellier, C; Maestro, C; Marcy, M; Ferrero, J-M; Flipo, B.
Afiliação
  • Ihrai T; Centre Antoine Lacassagne, Breast Cancer and Reconstructive Surgery Unit, France. Electronic address: t_ihrai@yahoo.fr.
  • Quaranta D; Centre Antoine Lacassagne, Breast Cancer and Reconstructive Surgery Unit, France.
  • Fouche Y; Centre Antoine Lacassagne, Breast Cancer and Reconstructive Surgery Unit, France.
  • Machiavello JC; Centre Antoine Lacassagne, Breast Cancer and Reconstructive Surgery Unit, France.
  • Raoust I; Centre Antoine Lacassagne, Breast Cancer and Reconstructive Surgery Unit, France.
  • Chapellier C; Centre Antoine Lacassagne, Radiology Unit, France.
  • Maestro C; Centre Antoine Lacassagne, Radiology Unit, France.
  • Marcy M; Centre Antoine Lacassagne, Pathology Unit, France.
  • Ferrero JM; Centre Antoine Lacassagne, Breast Cancer and Reconstructive Surgery Unit, France.
  • Flipo B; Centre Antoine Lacassagne, Breast Cancer and Reconstructive Surgery Unit, France.
Eur J Surg Oncol ; 40(4): 449-53, 2014 Apr.
Article em En | MEDLINE | ID: mdl-24468296
ABSTRACT
UNLABELLED A prospective study was lead in order to analyze the accuracy of an X-ray device settled in the operating room for margin assessment, when performing breast-conserving surgery. PATIENTS AND

METHODS:

One hundred and seventy patients were included. All lesions were visible on the preoperative mammograms. An intraoperative X-ray of the lumpectomy specimen was systematically performed for margins assessment. Final histological data were collected and the accuracy of intraoperative specimen radiography (IOSR) for margin assessment was analyzed.

RESULTS:

IOSR allowed an evaluation of margins status in 155 cases (91.2%). After final histological examination, the positive margins rate would have been 6.5% if margin assessment had relied only on IOSR.

CONCLUSION:

Margin assessment with a two-dimensional X-ray device would have allowed the achievement of negative margins in 93.5% of the cases. Moreover, this procedure allows important time-saving and could have a substantial economical impact.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Mastectomia Segmentar / Neoplasia Residual Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Eur J Surg Oncol Assunto da revista: NEOPLASIAS Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Mastectomia Segmentar / Neoplasia Residual Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Eur J Surg Oncol Assunto da revista: NEOPLASIAS Ano de publicação: 2014 Tipo de documento: Article