Your browser doesn't support javascript.
loading
Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging.
Kim, Hyunki; Arnoletti, Pablo J; Christein, John; Heslin, Martin J; Posey, James A; Pednekar, Amol; Mark Beasley, T; Morgan, Desiree E.
Afiliação
  • Kim H; Departments of Radiology, University of Alabama at Birmingham, Birmingham, AL, 35294-0019, USA, Hyunki@uab.edu.
Abdom Imaging ; 39(4): 744-52, 2014 Aug.
Article em En | MEDLINE | ID: mdl-24549880
PURPOSE: To confirm the feasibility of breath-hold DCE-MRI and DWI at 3T to obtain the intra-abdominal quantitative physiologic parameters, K(trans), k ep, and ADC, in patients with untreated pancreatic ductal adenocarcinomas. METHODS: Diffusion-weighted single-shot echo-planar imaging (DW-SS-EPI) and dynamic contrast-enhanced (DCE) MRI were used for 16 patients with newly diagnosed biopsy-proven pancreatic ductal adenocarcinomas. K(trans), k ep, and apparent diffusion coefficient (ADC) values of pancreatic tumors, non-tumor adjacent pancreatic parenchyma (NAP), liver metastases, and normal liver tissues were quantitated and statistically compared. RESULTS: Fourteen patients were able to adequately hold their breath for DCE-MRI, and 15 patients for DW-SS-EPI. Four patients had liver metastases within the 6 cm of Z axis coverage centered on the pancreatic primary tumors. K(trans) values (10(-3) min(-1)) of primary pancreatic tumors, NAP, liver metastases, and normal liver tissues were 7.3 ± 4.2 (mean ± SD), 25.8 ± 14.9, 8.1 ± 5.9, and 45.1 ± 15.6, respectively, k ep values (10(-2) min(-1)) were 3.0 ± 0.9, 7.4 ± 3.1, 5.2 ± 2.0, and 12.1 ± 2.8, respectively, and ADC values (10(-3) mm(2)/s) were 1.3 ± 0.2, 1.6 ± 0.3, 1.1 ± 0.1, and 1.3 ± 0.1, respectively. K(trans), k ep, and ADC values of primary pancreatic tumors were significantly lower than those of NAP (p < 0.05), while K(trans) and k ep values of liver metastases were significantly lower than those of normal liver tissues (p < 0.05). CONCLUSIONS: 3T breath-hold quantitative physiologic MRI is a feasible technique that can be applied to a majority of patients with pancreatic adenocarcinomas.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pâncreas / Neoplasias Pancreáticas / Adenocarcinoma / Imagem de Difusão por Ressonância Magnética Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Abdom Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pâncreas / Neoplasias Pancreáticas / Adenocarcinoma / Imagem de Difusão por Ressonância Magnética Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Abdom Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2014 Tipo de documento: Article