Konishi, Akihide; Shinke, Toshiro; Otake, Hiromasa; Takaya, Tomofumi; Nakagawa, Masayuki; Inoue, Takumi; Hariki, Hirotoshi; Osue, Tsuyoshi; Taniguchi, Yu; Iwasaki, Masamichi; Nishio, Ryo; Hiranuma, Noritoshi; Kinutani, Hiroto; Kuroda, Masaru; Takahashi, Hachidai; Terashita, Daisuke; Shite, Junya; Hirata, Ken-ichi.
Afiliação
  • Konishi A; Division of Cardiovascular and Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine.
Circ J ; 78(8): 1882-90, 2014.
Article em En | MEDLINE | ID: mdl-24909891
ABSTRACT

BACKGROUND:

Nobori is a novel biolimus A9-eluting stent (BES) coated with a biodegradable polymer only on the abluminal side, which degrades over 6-9 months post-stent deployment. The course of vessel reaction after deployment at these time points remains unclear. METHODS AND

RESULTS:

We serially evaluated 28 BES implanted in de novo coronary lesions of 23 patients using optical coherence tomography (OCT) at 6 and 12 months post-stenting. Standard OCT variables, the percentage of stent with peri-strut low-intensity area (PLIA, a region around stent struts homogenously showing lesser intensity than the surrounding tissue, suggesting fibrin deposition or impaired neointima maturation) and that with in-stent thrombi were evaluated. There was a significant, but small increase in neointimal thickness (72 ± 23 to 82 ± 25 µm, P=0.006) from the 6- to the 12-month follow-up, without a significant decrease in minimum lumen area (P=0.30). The incidences of uncovered and malapposed struts were low at 6 months and reduced further at 12 months (3.96 ± 3.97% to 1.51 ± 1.63%, P=0.001, and 0.50 ± 1.84% to 0.06 ± 0.24%, P=0.20, respectively). The frequency of stent with PLIA decreased during the follow-up (57% to 32%, P=0.05) and that with in-stent thrombi also numerically decreased (7% to 0%, P=0.24).

CONCLUSIONS:

Neointimal hyperplasia was persistently suppressed following BES implantation up to 12 months. Simultaneously, favorable vessel healing was achieved at 6 months without a delaying adverse reaction for up to 12 months.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Regeneração / Sirolimo / Tomografia de Coerência Óptica / Stents Farmacológicos / Plásticos Biodegradáveis Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Circ J Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2014 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Regeneração / Sirolimo / Tomografia de Coerência Óptica / Stents Farmacológicos / Plásticos Biodegradáveis Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Circ J Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2014 Tipo de documento: Article