Your browser doesn't support javascript.
loading
Infliximab treatment reduces tensile strength in intestinal anastomosis.
Jensen, Jonas Sanberg; Petersen, Nacie Bello; Biagini, Matteo; Bollen, Peter; Qvist, Niels.
Afiliação
  • Jensen JS; Department of Surgery, Kolding Hospital, Kolding, Denmark. Electronic address: jsanberg@dadlnet.dk.
  • Petersen NB; Faculty of Health Science, University of Southern Denmark, Odense, Denmark.
  • Biagini M; Department of Pathology, Odense University Hospital, Odense, Denmark.
  • Bollen P; Biomedical Laboratory, Faculty of Health Science, University of Southern Denmark, Odense Denmark.
  • Qvist N; Department of Surgery A, Odense University Hospital, Odense, Denmark. Electronic address: famqvist@dadlnet.dk.
J Surg Res ; 193(1): 145-52, 2015 Jan.
Article em En | MEDLINE | ID: mdl-25156230
BACKGROUND: The antitumor necrosis factor (infliximab [IFX]) has gained widespread use in the treatment of inflammatory bowel disease. However, several patients must undergo surgical treatment due to treatment failure and there is a potential risk that preoperative IFX treatment may have a negative effect on the healing process in intestinal anastomosis. The objective of this study was to examine the effect of repeated IFX treatment on anastomotic strength and degree of inflammation in the anastomotic line in the small intestine of rabbits. METHODS: Thirty-two rabbits were randomized (2:1) to receive either repeated IFX treatment or placebo. On day 15, three separate end-to-end anastomoses were performed on the jejunum. On postoperative day 5, tensile strength and bursting pressure for the anastomoses were tested and histologic changes examined. RESULTS: We found a significantly reduced tensile strength in the IFX group (1.94 ± 0.44 N) compared with the placebo group (3.33 ± 0.39 N), (P < 0.001). Calculation of Spearman correlation coefficients showed a positive significant correlation between minimal tensile strength and serum values of IFX (coefficient = -0.63; P = 0.003) as well as number of sutures in the tested anastomosis (coefficient = 0.51; P = 0.024). The general histologic score was significantly higher in the placebo group (5.00 ± 1.26 versus 3.31 ± 1.65, P = 0.03). CONCLUSIONS: Repeated high-dose IFX treatment reduces tensile strength significantly in rabbits and should be investigated further as a potential risk factor of anastomotic dehiscence in inflammatory bowel disease surgery.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Deiscência da Ferida Operatória / Resistência à Tração / Cicatrização / Anti-Inflamatórios não Esteroides / Anticorpos Monoclonais Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: J Surg Res Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Deiscência da Ferida Operatória / Resistência à Tração / Cicatrização / Anti-Inflamatórios não Esteroides / Anticorpos Monoclonais Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: J Surg Res Ano de publicação: 2015 Tipo de documento: Article