Assessment of inter-atrial, inter-ventricular, and atrio-ventricular interactions in tetralogy of Fallot patients after surgical correction. Insights from two-dimensional speckle tracking and three-dimensional echocardiography.
Cardiol Young
; 25(7): 1254-62, 2015 Oct.
Article
em En
| MEDLINE
| ID: mdl-25339059
ABSTRACT
BACKGROUND:
We aimed to assess biatrial size and function, interactions on atrial and ventricular levels, and atrio-ventricular coupling in patients after tetralogy of Fallot repair.METHODS:
A total of 34 patients with a mean age of 20.9±9 years, and 35 healthy controls, underwent two-dimensional speckle tracking echocardiography for ventricular and atrial strain measurements and real-time three-dimensional echocardiography to assess ventricular and atrial volumes.RESULTS:
When compared with controls, tetralogy of Fallot patients had significantly reduced right atrial peak atrial longitudinal strain (p<0.01), right atrial peak atrial contraction strain (p<0.01), right atrial ejection fraction (p<0.01), left atrial peak atrial longitudinal strain (p<0.01), left atrial peak atrial contraction strain (p<0.05), and left atrial ejection fraction (p<0.01). In the tetralogy of Fallot group, left ventricular ejection fraction was negatively related to the right ventricular end-systolic volume normalised to body surface area (r=-0.62, p<0.01). An association was found in patients between the right atrial peak longitudinal strain and mean right ventricular strain (r=0.64, p<0.01). In patients, the left atrial peak longitudinal strain correlated negatively with right atrial end-diastolic volume normalised to body surface area (r=-0.67, p<0.01), whereas the left atrial ejection fraction correlated weakly with left ventricular ejection fraction (r=0.41, p<0.05).CONCLUSIONS:
In asymptomatic tetralogy of Fallot patients, biatrial dysfunction exists and can be quantified via two-dimensional speckle tracking echocardiography as well as real-time three-dimensional echocardiography. Different forms of interactions on atrial and ventricular levels are evident among such cohorts.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Tetralogia de Fallot
/
Ecocardiografia Tridimensional
/
Átrios do Coração
/
Ventrículos do Coração
Tipo de estudo:
Observational_studies
/
Risk_factors_studies
Limite:
Adolescent
/
Adult
/
Child
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Cardiol Young
Assunto da revista:
ANGIOLOGIA
/
CARDIOLOGIA
/
PEDIATRIA
Ano de publicação:
2015
Tipo de documento:
Article
País de afiliação:
Alemanha