ABSTRACT

BACKGROUND:

From data collected during the third International Study on Mechanical Ventilation (ISMV), we compared data from a Dutch cohort with a European cohort. We hypothesised that tidal volumes were smaller and applied positive end-expiratory pressure (PEEP) was higher in the Netherlands, compared with the European cohort. We also compared use of non-invasive ventilation (NIV) and outcomes in both cohorts.

METHODS:

A post-hoc analysis of a prospective observational study of patients receiving mechanical ventilation.

RESULTS:

Tidal volumes were smaller (7.6 vs. 8.1 ml÷kg predicted bodyweight) in the Dutch cohort and applied PEEP was higher (8 vs. 6 cm H2O). Fewer patients admitted in the Netherlands received NIV as first mode of mechanical ventilation (7.1 vs. 16.7%). Fewer patients in the Dutch cohort developed an ICU-acquired pneumonia (4.5 vs. 12.3%, p < 0.01) and sepsis (5.7 vs. 10.9%, p = 0.03), but more patients were diagnosed as having delirium (15.8 vs. 4.6%, p < 0.01). ICU and in-hospital mortality rates were 19% and 25%, respectively, in Dutch ICUs vs. 26% and 33% in Europe (p = 0.06 and 0.03).

CONCLUSION:

Tidal volumes were smaller and applied PEEP was higher in the Dutch cohort compared with international data, but both Dutch and international patients received larger tidal volumes than recommended for prevention or treatment of acute respiratory distress syndrome. NIV as first mode of mechanical ventilation is less commonly used in the Netherlands. The incidence of ICU-acquired pneumonia is lower and of delirium higher in the Netherlands compared with international data.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração com Pressão Positiva / Sepse / Pneumonia Associada à Ventilação Mecânica / Ventilação não Invasiva / Unidades de Terapia Intensiva Tipo de estudo: Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Neth J Med Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Holanda
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração com Pressão Positiva / Sepse / Pneumonia Associada à Ventilação Mecânica / Ventilação não Invasiva / Unidades de Terapia Intensiva Tipo de estudo: Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Neth J Med Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Holanda