Your browser doesn't support javascript.
loading
Percutaneous transluminal balloon angioplasty in stenosis of native hemodialysis arteriovenous fistulas: technical success and analysis of factors affecting postprocedural fistula patency.
Aktas, Ayse; Bozkurt, Alper; Aktas, Bulent; Kirbas, Ismail.
Afiliação
  • Aktas A; Department of Radiology, Turgut Özal University School of Medicine, Ankara, Turkey. aysedag2029@yahoo.com.
Diagn Interv Radiol ; 21(2): 160-6, 2015.
Article em En | MEDLINE | ID: mdl-25698092
ABSTRACT

PURPOSE:

We aimed to determine the predictors of technical success and patency after percutaneous transluminal angioplasty (PTA) of de novo dysfunctional hemodialysis arteriovenous fistulas (AVF).

METHODS:

We performed a retrospective analysis of first time PTA in 228 patients (129 men, 99 women; mean age, 56.8±14.6 years). Anatomical (location, length, grade, and number of stenoses) and clinical variables (sex, age, prior AVF, diabetes mellitus, AVF age, side, and location) were reviewed.

RESULTS:

A total of 330 stenoses were found in 228 patients. PTA was technically successful in 96.3% of the stenoses (n=319). Clinical success was achieved in 97.2% (n=321). Early dysfunction (within six months) was positively correlated with patient age (P < 0.001) and diabetes (P < 0.005). Older age (P < 0.001) and diabetes (P = 0.002) were associated with a lower primary patency rate. Patient age (P %lt; 0.001), presence of diabetes (P = 0.023), length of stenosis (P = 0.003), early recurrence (P = 0.003) and presence of residual stenosis (P = 0.014) were associated with a lower secondary patency rate.

CONCLUSION:

Patency of dysfunctional hemodialysis fistulas can be maintained safely with continuous follow-up and repeated interventions without shortening the venous segment by surgical revision. Percutaneous approach to hemodialysis access stenosis is an alternative to the conventional surgical approach and PTA is an effective treatment method for dysfunctional AVF.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fístula Arteriovenosa / Diálise Renal / Angioplastia / Angioplastia com Balão Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Diagn Interv Radiol Assunto da revista: DIAGNOSTICO POR IMAGEM / RADIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fístula Arteriovenosa / Diálise Renal / Angioplastia / Angioplastia com Balão Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Diagn Interv Radiol Assunto da revista: DIAGNOSTICO POR IMAGEM / RADIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Turquia