Your browser doesn't support javascript.
loading
Clinical safety of an MRI conditional implantable cardioverter defibrillator system: A prospective Monocenter ICD-Magnetic resonance Imaging feasibility study (MIMI).
Kypta, Alexander; Blessberger, Hermann; Hoenig, Simon; Saleh, Karim; Lambert, Thomas; Kammler, Juergen; Fellner, Franz; Lichtenauer, Michael; Steinwender, Clemens.
Afiliação
  • Kypta A; Department of Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
  • Blessberger H; Department of Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
  • Hoenig S; Department of Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
  • Saleh K; Department of Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
  • Lambert T; Department of Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
  • Kammler J; Department of Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
  • Fellner F; Department of Radiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
  • Lichtenauer M; Department of Cardiology, Clinic of Internal Medicine II, Paracelsus Medical University of Salzburg, Salzburg, Austria.
  • Steinwender C; Department of Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
J Magn Reson Imaging ; 43(3): 574-84, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26335332

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Imageamento por Ressonância Magnética / Desfibriladores Implantáveis Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Imageamento por Ressonância Magnética / Desfibriladores Implantáveis Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Áustria