Your browser doesn't support javascript.
loading
Surgical implantation and functional assessment of an invasive telemetric system to measure autonomic responses in domestic pigs.
Krause, A; Zebunke, M; Bellmann, O; Mohr, E; Langbein, J; Puppe, B.
Afiliação
  • Krause A; Institute of Behavioural Physiology, Leibniz Institute for Farm Animal Biology (FBN), D-18196 Dummerstorf, Germany.
  • Zebunke M; Institute of Behavioural Physiology, Leibniz Institute for Farm Animal Biology (FBN), D-18196 Dummerstorf, Germany.
  • Bellmann O; Scientific Organisation and Service, Leibniz Institute for Farm Animal Biology (FBN), D-18196 Dummerstorf, Germany.
  • Mohr E; Animal Health and Welfare, Faculty of Agricultural and Environmental Sciences, University of Rostock, D-18059 Rostock, Germany.
  • Langbein J; Institute of Behavioural Physiology, Leibniz Institute for Farm Animal Biology (FBN), D-18196 Dummerstorf, Germany. Electronic address: langbein@fbn-dummerstorf.de.
  • Puppe B; Institute of Behavioural Physiology, Leibniz Institute for Farm Animal Biology (FBN), D-18196 Dummerstorf, Germany; Behavioural Sciences, Faculty of Agricultural and Environmental Sciences, University of Rostock, D-18059 Rostock, Germany. Electronic address: puppe@fbn-dummerstorf.de.
Vet J ; 207: 140-146, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26626089
ABSTRACT
The first aim of this study was to establish a surgical procedure to implant a new telemetric device for the continuous recording of electrocardiogram (ECG) and blood pressure (BP) in freely moving pigs. A second aim was the functional assessment of cardiovascular parameters, including heart rate variability (HRV) and blood pressure variability (BPV), so that these data could be used as the basis for the objective evaluation of autonomic activity and balance in different behavioural contexts. Eleven domestic pigs (German Landrace) underwent surgery for the placement of a telemetric device. At day 15 after surgery, 512 consecutive inter-beat intervals and pressure waves were analysed using different detection methods (automatic and manually corrected) while the animals were resting or feeding, respectively. HRV and BPV were calculated. Incomplete datasets were found in four pigs due to missing ECG or BP signals. Technical and surgical issues concerning catheterisation and detachment of the negative ECG lead were continuously improved. In the remaining pigs, excellent signal quality (manually corrected data of 1%) was obtained during resting and acceptable signal quality (<10%) was obtained during feeding. Automatic triggering was sufficiently reliable to eliminate errors in BP recordings during active behaviour, but this was not the case for ECG recordings. Sympathetic arousal with accompanying vagal withdrawal during feeding was documented. The established surgical implantation and functional assessment of the telemetric system with the reliable registration of cardiovascular parameters in freely moving pigs could serve as a basis for future studies of autonomic regulation in context of stress and animal welfare.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Suínos / Telemetria / Eletrocardiografia / Frequência Cardíaca Limite: Animals Idioma: En Revista: Vet J Assunto da revista: MEDICINA VETERINARIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Suínos / Telemetria / Eletrocardiografia / Frequência Cardíaca Limite: Animals Idioma: En Revista: Vet J Assunto da revista: MEDICINA VETERINARIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha