Your browser doesn't support javascript.
loading
Monolithic metal-organic framework MIL-53(Al)-polymethacrylate composite column for the reversed-phase capillary liquid chromatography separation of small aromatics.
Yusuf, Kareem; Badjah-Hadj-Ahmed, Ahmed Yacine; Aqel, Ahmad; ALOthman, Zeid Abdullah.
Afiliação
  • Yusuf K; Advanced Materials Research Chair, Department of Chemistry, College of Science, King Saud University, Riyadh, Kingdom of Saudi Arabia.
  • Badjah-Hadj-Ahmed AY; Advanced Materials Research Chair, Department of Chemistry, College of Science, King Saud University, Riyadh, Kingdom of Saudi Arabia.
  • Aqel A; Advanced Materials Research Chair, Department of Chemistry, College of Science, King Saud University, Riyadh, Kingdom of Saudi Arabia.
  • ALOthman ZA; Advanced Materials Research Chair, Department of Chemistry, College of Science, King Saud University, Riyadh, Kingdom of Saudi Arabia.
J Sep Sci ; 39(5): 880-8, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26711438
A monolithic capillary column containing a composite of metal-organic framework MIL-53(Al) incorporated into hexyl methacrylate-co-ethylene dimethacrylate was prepared to enhance the separation of mixtures of small aromatic compounds by using capillary liquid chromatography. The addition of 10 mg/mL MIL-53(Al) microparticles increased the micropore content in the monolithic matrix and increased the Brunauer-Emmett-Teller surface area from 26.92 to 85.12 m(2) /g. The presence of 1,4-benzenedicarboxylate moieties within the structure of MIL-53(Al) as an organic linker greatly influenced the separation of aromatic mixtures through π-π interactions. High-resolution separation was obtained for a series of alkylbenzenes (with resolution factors in the range 0.96-1.75) in less than 8 min, with 14 710 plates/m efficiency for propylbenzene, using a binary polar mobile phase of water/acetonitrile in isocratic mode. A reversed-phase separation mechanism was indicated by the increased retention factor and resolution as the water percentage in the mobile phase increased. A stability study on the composite column showed excellent mechanical stability under various conditions. The higher resolution and faster separation observed at increased temperature indicated an exothermic separation, whereas the negative values for the free energy change of transfer indicated a spontaneous process.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Sep Sci Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Sep Sci Ano de publicação: 2016 Tipo de documento: Article