Your browser doesn't support javascript.
loading
Signal decay mapping of myocardial edema using dual-contrast fast spin-echo MRI.
Krumm, Patrick; Martirosian, Petros; Rath, Dominik; Zitzelsberger, Tanja; Ruff, Christer Andreas; Klumpp, Bernhard Daniel; Nikolaou, Konstantin; Gawaz, Meinrad; Geisler, Tobias; Schick, Fritz; Kramer, Ulrich.
Afiliação
  • Krumm P; Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tübingen, Germany.
  • Martirosian P; Department of Diagnostic and Interventional Radiology, Section on Experimental Radiology, Eberhard Karls University, Tübingen, Germany.
  • Rath D; Department of Cardiology and Cardiovascular Medicine, Eberhard Karls University, Tübingen, Germany.
  • Zitzelsberger T; Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tübingen, Germany.
  • Ruff CA; Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tübingen, Germany.
  • Klumpp BD; Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tübingen, Germany.
  • Nikolaou K; Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tübingen, Germany.
  • Gawaz M; Department of Cardiology and Cardiovascular Medicine, Eberhard Karls University, Tübingen, Germany.
  • Geisler T; Department of Cardiology and Cardiovascular Medicine, Eberhard Karls University, Tübingen, Germany.
  • Schick F; Department of Diagnostic and Interventional Radiology, Section on Experimental Radiology, Eberhard Karls University, Tübingen, Germany.
  • Kramer U; Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tübingen, Germany.
J Magn Reson Imaging ; 44(1): 186-93, 2016 07.
Article em En | MEDLINE | ID: mdl-26717865
ABSTRACT

PURPOSE:

To introduce a dual-contrast fast spin-echo (dcFSE) sequence for signal decay mapping of myocardial edema. MATERIALS AND

METHODS:

After consultation with the Institutional Review Board, 22 acute myocardial infarction (MI) patients were examined with magnetic resonance imaging (MRI) at 1.5T 2 days after revascularization. Edema was evaluated in 16 myocardial segments with an exponential fit for signal decay time (SDT) in dcFSE mapping and T2 signal intensity ratio for single-contrast FSE. Myocardial viability was evaluated in late gadolinium enhancement (LGE). A control group of 10 volunteers was examined for edema imaging. SDT was compared in segment groups 1) with LGE in MI, 2) penumbra, 3) remote from LGE, 4) controls. Groups 1/3 and 3/4 were tested on difference. Three phantoms providing similar T2 but different T1 relaxation times (low, intermediate, high) were examined with dcFSE and multicontrast spin echo sequence as a reference.

RESULTS:

The SDT/T2 ratio for segment groups was 1) 82msec/1.7 in segments with LGE; 2) 65msec/1.6 for penumbra, 3) 62msec/1.7 for remote segments, and 4) 50msec/1.6 in controls. In dcFSE group 1/3 (P < 0.0001) and in group 3/4 (P = 0.0002) SDT was significantly different. In single-contrast FSE the T2 ratio was not significantly different for both tests 1/3 P = 0.1889; 3/4 P = 0.8879. T2 -overestimation of dcFSE was 23% in low, 29% in intermediate, and 35% in highly T1 contaminated phantoms.

CONCLUSION:

dcFSE signal decay edema mapping is feasible in volunteers and patients. DcFSE SDT is superior to T2 ratio for detection of high-grade and diffuse myocardial edema. J. Magn. Reson. Imaging 2016;44186-193.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Interpretação de Imagem Assistida por Computador / Imagem Cinética por Ressonância Magnética / Edema Cardíaco / Técnicas de Imagem Cardíaca Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Interpretação de Imagem Assistida por Computador / Imagem Cinética por Ressonância Magnética / Edema Cardíaco / Técnicas de Imagem Cardíaca Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha