Your browser doesn't support javascript.
loading
Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes.
Taylor, I Mitch; Robbins, Elaine M; Catt, Kasey A; Cody, Patrick A; Happe, Cassandra L; Cui, Xinyan Tracy.
Afiliação
  • Taylor IM; University of Pittsburgh, Department of Bioengineering, 3501 Fifth Ave., Pittsburgh, PA 15261, USA.
  • Robbins EM; University of Pittsburgh, Department of Chemistry, 219 Parkman Ave., Pittsburgh, PA 15260, USA.
  • Catt KA; University of Pittsburgh, Department of Bioengineering, 3501 Fifth Ave., Pittsburgh, PA 15261, USA.
  • Cody PA; University of Pittsburgh, Department of Bioengineering, 3501 Fifth Ave., Pittsburgh, PA 15261, USA.
  • Happe CL; University of California, San Diego, Department of Bioengineering, 9500 Gilman Dr., La Jolla, CA 92093, USA.
  • Cui XT; University of Pittsburgh, Department of Bioengineering, 3501 Fifth Ave., Pittsburgh, PA 15261, USA. Electronic address: xic11@pitt.edu.
Biosens Bioelectron ; 89(Pt 1): 400-410, 2017 Mar 15.
Article em En | MEDLINE | ID: mdl-27268013
ABSTRACT
Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Dopamina / Compostos Bicíclicos Heterocíclicos com Pontes / Corpo Estriado / Técnicas Eletroquímicas / Grafite Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Dopamina / Compostos Bicíclicos Heterocíclicos com Pontes / Corpo Estriado / Técnicas Eletroquímicas / Grafite Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos