Your browser doesn't support javascript.
loading
Optimal ROI setting on the anatomically normalized I-123 FP-CIT images using high-resolution SPECT.
Nonokuma, Masanari; Kuwabara, Yasuo; Hida, Kosuke; Tani, Tomonobu; Takano, Koichi; Yoshimitsu, Kengo.
Afiliação
  • Nonokuma M; Department of Radiology, Fukuoka University Hospital, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan. nono@fukuoka-u.ac.jp.
  • Kuwabara Y; Department of Radiology, Fukuoka University Hospital, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan.
  • Hida K; Department of Radiology, Fukuoka University Hospital, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan.
  • Tani T; Department of Radiology, Fukuoka University Hospital, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan.
  • Takano K; Department of Radiology, Fukuoka University Hospital, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan.
  • Yoshimitsu K; Department of Radiology, Fukuoka University Hospital, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan.
Ann Nucl Med ; 30(9): 637-644, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27438050
ABSTRACT

OBJECTIVE:

The aim of this study is to establish the optimal regions of interest (ROIs) in anatomically normalized I-123 FP-CIT SPECT images for the quantification of dopamine transporter binding.

METHODS:

The subjects comprised 16 normal controls and 14 Parkinsonian patients. All of the normal control subjects underwent I-123 FP-CIT SPECT and MRI. The SPECT device used in this study was a Toshiba GCA-9300R with triple head detectors. I-123 FP-CIT (148 MBq) was intravenously administered as a bolus, and the SPECT scan started 4 h after the administration. The data were collected over 20 min for each subject, and reconstructed using a 3D-OSEM algorithm. The data were analyzed using SPM8. I-123 FP-CIT SPECT images were anatomically normalized to the MNI space using an I-123 FP-CIT template, and then divided by the background counts automatically measured using the ROIs set for the cerebral cortices.

RESULTS:

In the normal control subjects, the specific binding ratios of the MRI-based ROIs were lowest in the caudate nucleus, while the ratios of the I-123 FP-CIT-based ROIs were almost the same throughout all three parts. In contrast, in Parkinsonian patients, the specific binding ratios of the I-123 FP-CIT-based ROIs revealed rostrocaudal decline, while those of the MRI-based ROIs were highest in the anterior putamen.

CONCLUSION:

We created an ROI template on the anatomically normalized MRI and I-123 FP-CIT images, and concluded that I-123 FP-CIT-based ROIs are more suitable for obtaining quantitative values than MRI-based ones.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tropanos / Tomografia Computadorizada de Emissão de Fóton Único / Anatomia Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Nucl Med Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tropanos / Tomografia Computadorizada de Emissão de Fóton Único / Anatomia Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Nucl Med Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Japão