Your browser doesn't support javascript.
loading
Three-dimensional dynamic morphology of the mitral valve in different forms of mitral valve prolapse - potential implications for annuloplasty ring selection.
Apor, Astrid; Nagy, Anikó Ilona; Kovács, Attila; Manouras, Aristomenis; Andrássy, Péter; Merkely, Béla.
Afiliação
  • Apor A; Heart and Vascular Center, Semmelweis University, Gaál J.u.9, Budapest, H-1122, Hungary.
  • Nagy AI; Heart and Vascular Center, Semmelweis University, Gaál J.u.9, Budapest, H-1122, Hungary. anychophora@gmail.com.
  • Kovács A; Heart and Vascular Center, Semmelweis University, Gaál J.u.9, Budapest, H-1122, Hungary.
  • Manouras A; Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden.
  • Andrássy P; Bajcsy-Zsilinszky Hospital and Clinic, Budapest, Hungary.
  • Merkely B; Heart and Vascular Center, Semmelweis University, Gaál J.u.9, Budapest, H-1122, Hungary.
Cardiovasc Ultrasound ; 14(1): 32, 2016 Aug 15.
Article em En | MEDLINE | ID: mdl-27528216
BACKGROUND: Real-time three-dimensional transesophageal echocardiography has increased our understanding of the distinct pathomechanisms underlying functional, ischaemic or degenerative mitral regurgitation. However, potential differences in dynamic morphology between the subtypes of degenerative mitral prolapse have scarcely been investigated. METHODS: In order to compare the dynamic behavior of the different phenotypes of degenerative mitral valve prolapse, real-time three-dimensional transesophageal echocardiography recordings of 77 subjects, 27 with Barlow disease (BD), 32 with Fibroelastic deficiency (FED) and 18 normal controls (NC) were analysed. RESULTS: Geometric annular and valvular parameters of the myxomatous patients were significantly larger compared to controls (BD vs. FED vs. NC 3D annular area: 15 ± 2.8 vs. 13.3 ± 2.4 vs. 10.6 ± 2.3cm(2), all p < 0.01). Beside similar ellipticity, BD annuli were significantly flatter compared to FED. Myxomatous annuli appeared less dynamic than normals, with decreased overall 3D area change, however only the BD group differed from NC significantly (BD vs. FED vs. NC normalized 3D area change 4.40 vs. 6.81 vs. 9.69 %; BD vs. NC p = 0.000; FED vs. NC p = not significant, BD vs. FED p = 0.025). CONCLUSION: BD and FED differ not only in terms of valve morphology, but also annular dynamics. Both pathologies are characterized by annular dilatation. However, in BD the annulus is remarkably flattened and hypodynamic, whereas in FED its saddle-shape and contractile function is relatively preserved. These features might influence the choice of repair technique and the selection of annuloplasty ring.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses Valvulares Cardíacas / Prolapso da Valva Mitral / Ecocardiografia Transesofagiana / Ecocardiografia Tridimensional / Anuloplastia da Valva Cardíaca / Valva Mitral Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Ultrasound Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Hungria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses Valvulares Cardíacas / Prolapso da Valva Mitral / Ecocardiografia Transesofagiana / Ecocardiografia Tridimensional / Anuloplastia da Valva Cardíaca / Valva Mitral Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Ultrasound Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Hungria