Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning.
Eur Radiol
; 27(5): 1944-1953, 2017 May.
Article
em En
| MEDLINE
| ID: mdl-27553939
ABSTRACT
PURPOSE:
To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). MATERIALS ANDMETHODS:
Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured.RESULTS:
Besides a higher body-mass-index in group B (24.8±3.8 kg/m2 vs. 28.1±5.4 kg/m2, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302).CONCLUSION:
TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. KEY POINTS ⢠Third-generation dual-source CT facilitates low-tube-voltage acquisition. ⢠TAVR planning can be performed with reduced contrast volume and radiation dose. ⢠TAVR-planning CT did not result in changes in creatinine levels at follow-up. ⢠TAVR candidates can be safely evaluated by comprehensive low-tube-voltage CT angiography.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Estenose da Valva Aórtica
/
Substituição da Valva Aórtica Transcateter
/
Angiografia por Tomografia Computadorizada
Tipo de estudo:
Evaluation_studies
/
Observational_studies
Limite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Eur Radiol
Assunto da revista:
RADIOLOGIA
Ano de publicação:
2017
Tipo de documento:
Article
País de afiliação: