Reduction of falls and fractures after permanent pacemaker implantation in elderly patients with sinus node dysfunction.
Brenner, Roman; Ammann, Peter; Yoon, See-Il; Christen, Stefan; Hellermann, Jens; Girod, Grégoire; Knaus, Urs; Duru, Firat; Krasniqi, Nazmi; Ramsay, David; Sticherling, Christian; Lippuner, Kurt; Kühne, Michael.
Afiliação
  • Brenner R; Kantonsspital St. Gallen, St. Gallen, Switzerland.
  • Ammann P; Kantonsspital St. Gallen, St. Gallen, Switzerland.
  • Yoon SI; Luzerner Kantonsspital Sursee, Sursee, Switzerland.
  • Christen S; Stadtspital Waid, Zürich, Switzerland.
  • Hellermann J; Spitalregion RWS St. Gallen, St. Gallen, Switzerland.
  • Girod G; Hopital de Sion, Sion, Switzerland.
  • Knaus U; Spital Herisau, Herisau, Switzerland.
  • Duru F; University of Zurich, Zurich, Switzerland.
  • Krasniqi N; GZO Spital Wetzikon, Wetzikon, Switzerland.
  • Ramsay D; Zuger Kantonsspital, Zug, Switzerland.
  • Sticherling C; Cardiology/Electrophysiology, University of Basel, Basel, Switzerland.
  • Lippuner K; Policlinic for Osteoporosis, University and University Hospital of Bern, Bern, Switzerland.
  • Kühne M; Cardiology/Electrophysiology, University of Basel, Basel, Switzerland.
Europace ; 19(7): 1220-1226, 2017 Jul 01.
Article em En | MEDLINE | ID: mdl-27702858
ABSTRACT

AIMS:

Elderly patients with sinus node dysfunction (SND) are at increased risk of falls with possible injuries. However, the incidence of these adverse events and its reduction after permanent pacemaker (PPM) implantation are not known. METHODS AND

RESULTS:

Eighty-seven patients (mean [SD] age 75.4 [8.3] years, 51% women) with SND and an indication for cardiac pacing were included and were examined by a standardized interview targeting fall history. The incidence and total number of falls, falls with injury, falls requiring treatment, and falls resulting in a fracture were assessed for the time period of 12 months before (retrospectively) and after PPM implantation (prospectively). Furthermore, symptoms such as syncope, dizziness, and dyspnea were evaluated before and after PPM implantation. The implantation of a PPM was associated with a reduced proportion of patients experiencing at least one fall by 71% (from 53 to 15%, P < 0.001) and a reduction of the absolute number of falls by 90% (from 127 to 13, P < 0.001) during the 12 months before vs. after PPM implant. Falls with injury (28 vs. 10%, P = 0.005), falls requiring medical attention (31 vs. 8%, P < 0.001), and falls leading to fracture (8 vs. 0%, P = 0.013) were similarly reduced. Notably, fewer patients had syncope (4 vs. 45%, P < 0.001) and dizziness after PPM implantation (12 vs. 45%, P < 0.001).

CONCLUSION:

Falls, fall-related injuries, and fall-related fractures are frequent in SND patients. Permanent pacemaker implantation is associated with a significantly reduced risk of these adverse events, although no causal relationship could be established due to the study design.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Síndrome do Nó Sinusal / Acidentes por Quedas / Estimulação Cardíaca Artificial Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Síndrome do Nó Sinusal / Acidentes por Quedas / Estimulação Cardíaca Artificial Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Suíça