Your browser doesn't support javascript.
loading
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors.
Plaud-Ramos, K O; Freeman, M S; Wei, W; Guardincerri, E; Bacon, J D; Cowan, J; Durham, J M; Huang, D; Gao, J; Hoffbauer, M A; Morley, D J; Morris, C L; Poulson, D C; Wang, Zhehui.
Afiliação
  • Plaud-Ramos KO; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Freeman MS; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Wei W; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Guardincerri E; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Bacon JD; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Cowan J; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Durham JM; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Huang D; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Gao J; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Hoffbauer MA; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Morley DJ; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Morris CL; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Poulson DC; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
  • Wang Z; Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
Rev Sci Instrum ; 87(11): 11E706, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27910424
ABSTRACT
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a 90Sr ß-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnSAg phosphor screen and optics. Noise reduction in CIS is nevertheless important for the indirect approach.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos