Mutation Profile and Fluorescence In Situ Hybridization Analyses Increase Detection of Malignancies in Biliary Strictures.
Clin Gastroenterol Hepatol
; 15(6): 913-919.e1, 2017 Jun.
Article
em En
| MEDLINE
| ID: mdl-28017843
BACKGROUND & AIMS: It is a challenge to detect malignancies in biliary strictures. Various sampling methods are available to increase diagnostic yield, but these require additional procedure time and expertise. We evaluated the combined accuracy of fluorescence in situ hybridization (FISH) and polymerase chain reaction-based DNA mutation profiling (MP) of specimens collected using standard brush techniques. METHODS: We performed a prospective study of 107 consecutive patients treated for biliary strictures by endoscopic retrograde cholangiopancreatography from June 2012 through June 2014. We performed routine cytology and FISH analyses on cells collected by standard brush techniques, and analyzed supernatants for point mutations in KRAS and loss-of-heterozygosity mutations in tumor-suppressor genes at 10 loci (MP analysis was performed at Interpace Diagnostics). Strictures were determined to be nonmalignant based on repeat image analysis or laboratory test results 12 months after the procedure. Malignant strictures were identified based on subsequent biopsy or cytology analyses, pathology analyses of samples collected during surgery, or death from biliary malignancy. We determined the sensitivity and specificity with which FISH and MP analyses detected malignancies using the exact binomial test. RESULTS: Our final analysis included 100 patients; 41% had biliary malignancies. Cytology analysis identified patients with malignancies with 32% sensitivity and 100% specificity. Addition of FISH or MP results to cytology results increased the sensitivity of detection to 51% (P < .01) without reducing specificity. The combination of cytology, MP, and FISH analyses detected malignancies with 73% sensitivity (P < .001). FISH identified an additional 9 of the 28 malignancies not detected by cytology analysis, and MP identified an additional 8 malignancies. FISH and MP together identified 17 of the 28 malignancies not detected by cytology analysis. CONCLUSIONS: Addition of FISH and mutation analyses to cytology analysis significantly increased the level of sensitivity with which we detected malignancy in biliary strictures, with 100% specificity. These techniques can be performed using standard brush samples collected during endoscopic retrograde cholangiopancreatography, with mutations detected in free DNA in supernatant fluid of samples. The tests are complementary and therefore should be used sequentially in the diagnostic evaluation of biliary strictures.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Colestase Extra-Hepática
/
Neoplasias do Sistema Biliar
/
Hibridização in Situ Fluorescente
/
Constrição Patológica
/
Técnicas de Diagnóstico Molecular
/
Técnicas de Genotipagem
Tipo de estudo:
Diagnostic_studies
/
Evaluation_studies
/
Observational_studies
/
Prognostic_studies
Limite:
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Clin Gastroenterol Hepatol
Assunto da revista:
GASTROENTEROLOGIA
Ano de publicação:
2017
Tipo de documento:
Article