Your browser doesn't support javascript.
loading
Influence of continuously evolving transcatheter aortic valve implantation technology on cerebral oxygenation.
Eertmans, Ward; Genbrugge, Cornelia; Fret, Tom; Beran, Maud; Engelen, Kim; Gutermann, Herbert; Vander Laenen, Margot; Boer, Willem; Ferdinande, Bert; Jans, Frank; Dens, Jo; De Deyne, Cathy.
Afiliação
  • Eertmans W; Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium. ward.eertmans@uhasselt.be.
  • Genbrugge C; Faculty of Medicine and Life Sciences, Hasselt University, Martelarenlaan 42, 3500, Hasselt, Belgium. ward.eertmans@uhasselt.be.
  • Fret T; Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
  • Beran M; Faculty of Medicine and Life Sciences, Hasselt University, Martelarenlaan 42, 3500, Hasselt, Belgium.
  • Engelen K; Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
  • Gutermann H; Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
  • Vander Laenen M; Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
  • Boer W; Department of Cardiac Surgery, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
  • Ferdinande B; Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
  • Jans F; Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
  • Dens J; Department of Cardiology, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
  • De Deyne C; Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium.
J Clin Monit Comput ; 31(6): 1133-1141, 2017 Dec.
Article em En | MEDLINE | ID: mdl-28025751
This study assessed the influence of the evolution in Transcatheter Aortic Valve Implantation technology on cerebral oxygenation. Cerebral oxygenation was measured continuously with Near-Infrared Spectroscopy and compared retrospectively between balloon-expandable, self-expandable and differential deployment valves which were implanted in 12 (34%), 17 (49%) and 6 patients (17%), respectively. Left and right SctO2 values were averaged at four time points and used for analysis (i.e. at baseline, balloon-aortic valvuloplasty, valve deployment, and at the end of the procedure). During balloon-aortic valvuloplasty and valve deployment, cerebral oxygenation decreased in patients treated with balloon or self-expandable valves (balloon-expandable: p = 0.003 and p = 0.002; self-expandable: p < 0.001 and p = 0.003, respectively). The incidence of cerebral desaturations below 80% of baseline was significantly larger in patients treated with balloon-expandable valves (p = 0.001). In contrast, patients who received differential deployment valves never experienced a cerebral desaturation below 80% of baseline. Furthermore, both the incidence and duration below a cerebral oxygenation of 55% was significantly different between balloon and self-expandable valves (p = 0.038 and p = 0.018, respectively). This study demonstrated that Transcatheter Aortic Valve Implantation procedures are associated with significant cerebral desaturations, especially during balloon-aortic valvuloplasty and valve deployment. Moreover, our results showed that latest innovations in Transcatheter Aortic Valve Implantation technology beneficially influenced the adequacy of cerebral perfusion.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Oxigênio / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Circulação Cerebrovascular / Substituição da Valva Aórtica Transcateter Tipo de estudo: Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Oxigênio / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Circulação Cerebrovascular / Substituição da Valva Aórtica Transcateter Tipo de estudo: Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Bélgica