Your browser doesn't support javascript.
loading
Fluorescein Diacetate Microplate Assay in Cell Viability Detection.
Chen, Xi; Yang, Xiu-Ying; Fang, Lian-Hua; DU, Guan-Hua.
Afiliação
  • Chen X; Beijing Key Laboratory of Drug Target Identification and Drug Screening,Institute of Materia Medica, CAMS and PUMC,Beijing 100050,China.
  • Yang XY; Beijing Key Laboratory of Drug Target Identification and Drug Screening,Institute of Materia Medica, CAMS and PUMC,Beijing 100050,China.
  • Fang LH; Beijing Key Laboratory of Drug Target Identification and Drug Screening,Institute of Materia Medica, CAMS and PUMC,Beijing 100050,China.
  • DU GH; Beijing Key Laboratory of Drug Target Identification and Drug Screening,Institute of Materia Medica, CAMS and PUMC,Beijing 100050,China.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 38(6): 710-714, 2016 Dec 20.
Article em En | MEDLINE | ID: mdl-28065239
Objective To investigate the application of the fluorescein diacetate (FDA) microplate assay in cell viability detection. Methods Cells were seeded in a 96-well culture plate until detection. After incubated with FDA,the plate was detected by fluorescence microplate analyzer. The effects of FDA incubation duration,concentration,and other factors on the assay's accuracy and stability were assessed. We also compared the results of FDA with methyl thiazolyl(MTT) in terms of cell numbers and H2O2 injury. Results Within 0-30 minutes,the fluorescence-cell number coefficient of FDA assay increased with duration and reached 0.99 in 27-30 minutes. The optimum concentration of final FDA in this study was 10-30 µg/ml. On cell viability detection,the result of FDA method was equivalent to MTT method. As to H2O2 injury assay,the sensitivity of FDA method was superior to MTT on the higher concentration H2O2 treatment due to a relative shorter duration for detection. Conclusion As a stable and reliable method,FDA is feasible for cell variability detection under varied conditions.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sobrevivência Celular / Fluoresceínas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sobrevivência Celular / Fluoresceínas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China