Your browser doesn't support javascript.
loading
Influence of tibial hybrid fixation on graft tension and stability in ACL double-bundle reconstruction.
Drews, B H; Seitz, A; Huth, J; Bauer, G; Ignatius, A; Dürselen, L.
Afiliação
  • Drews BH; Department for Orthopedic Trauma, Hand and Reconstructive Surgery, Center of Surgery, University of Ulm, Albert-Einstein-Allee 23, 89081, Ulm, Germany. b.drews@me.com.
  • Seitz A; Trauma Research Center, Institute of Orthopedic Research and Biomechanics, University of Ulm-Medical Center, Helmholtzstraße 14, 89081, Ulm, Germany.
  • Huth J; Sportklinik Stuttgart GmbH, Taubenheimstraße 8, 70734, Stuttgart, Germany.
  • Bauer G; Sportklinik Stuttgart GmbH, Taubenheimstraße 8, 70734, Stuttgart, Germany.
  • Ignatius A; Trauma Research Center, Institute of Orthopedic Research and Biomechanics, University of Ulm-Medical Center, Helmholtzstraße 14, 89081, Ulm, Germany.
  • Dürselen L; Trauma Research Center, Institute of Orthopedic Research and Biomechanics, University of Ulm-Medical Center, Helmholtzstraße 14, 89081, Ulm, Germany.
Arch Orthop Trauma Surg ; 137(7): 981-988, 2017 Jul.
Article em En | MEDLINE | ID: mdl-28424860
ABSTRACT

PURPOSE:

Initial graft tension in anterior cruciate ligament (ACL) reconstruction affects stability and tension loss at follow-up. This study investigated the influence of hybrid tibial fixation in 3-tunnel double-bundle ACL reconstruction on initial graft tension and tension change and stability under anterior and combined rotatory loads.

METHODS:

Eleven fresh-frozen cadaveric knees were reconstructed with an ACL double bundle using a 3-tunnel technique. Grafts were tightened to 80 N in 60° (AM bundle) and 15° (PL bundle) of flexion. Anterior tibial translation under 134 N of anterior shear load and translation under combined rotatory and valgus loads (10 Nm valgus stress, 4 Nm internal tibial torque) were determined at 0°, 30°, 60°, and 90° flexion. In addition, graft tension under continuous passive motion was determined. Intact, ACL-resected and ACL-reconstructed joints with either tibial extracortical graft fixation or extracortical plus supplemental aperture graft fixation (hybrid fixation) were tested.

RESULTS:

Hybrid fixation did not increase graft tension in either bundle during fixation or in motion without additional load. AM-bundle tension increased (p < 0.05) at 0° under combined rotatory and valgus loads and at 30° and 60° under both loading conditions without decreasing the anterior tibial translation. PL-bundle tension increased (p < 0.05) only at 90° under combined rotatory and valgus loads.

CONCLUSIONS:

Tibial hybrid fixation in 3-tunnel double-bundle ACL reconstruction increases time-zero AM- and PL-bundle tensions under loading conditions, generating greater construct stiffness. This could lead to a longer preservation of ACL-graft stability in clinical follow-up before bony incorporation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tíbia / Ligamento Cruzado Anterior / Transplantes Limite: Aged / Female / Humans / Middle aged Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tíbia / Ligamento Cruzado Anterior / Transplantes Limite: Aged / Female / Humans / Middle aged Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha