Your browser doesn't support javascript.
loading
A Single-Ion Reservoir as a High-Sensitive Sensor of Electric Signals.
Domínguez, Francisco; Arrazola, Iñigo; Doménech, Jaime; Pedernales, Julen S; Lamata, Lucas; Solano, Enrique; Rodríguez, Daniel.
Afiliação
  • Domínguez F; Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, Campus de Fuentenueva s/n, 18071, Granada, Spain.
  • Arrazola I; Department of Physical Chemistry, University of the Basque Country UPV/EHU, Apartado 644, 48080, Bilbao, Spain.
  • Doménech J; Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, Campus de Fuentenueva s/n, 18071, Granada, Spain.
  • Pedernales JS; Department of Physical Chemistry, University of the Basque Country UPV/EHU, Apartado 644, 48080, Bilbao, Spain.
  • Lamata L; Department of Physical Chemistry, University of the Basque Country UPV/EHU, Apartado 644, 48080, Bilbao, Spain.
  • Solano E; Department of Physical Chemistry, University of the Basque Country UPV/EHU, Apartado 644, 48080, Bilbao, Spain.
  • Rodríguez D; IKERBASQUE, Basque Foundation for Science, Maria Diaz de Haro 3, 48013, Bilbao, Spain.
Sci Rep ; 7(1): 8336, 2017 08 21.
Article em En | MEDLINE | ID: mdl-28827533
A single-ion reservoir has been tested, and characterized in order to be used as a highly sensitive optical detector of electric signals arriving at the trapping electrodes. Our system consists of a single laser-cooled 40Ca+ ion stored in a Paul trap with rotational symmetry. The performance is observed through the axial motion of the ion, which is equivalent to an underdamped and forced oscillator. Thus, the results can be projected also to Penning traps. We have found that, for an ion oscillator temperature T axial ≲ 10 mK in the forced-frequency range ω z = 2π × (80,200 kHz), the reservoir is sensitive to a time-varying electric field equivalent to an electric force of 5.3(2) neV/µm, for a measured quality factor Q = 3875(45), and a decay time constant γ z = 88(2) s-1. This method can be applied to measure optically the strength of an oscillating field or induced (driven) charge in this frequency range within times of tens of milliseconds. Furthermore the ion reservoir has been proven to be sensitive to electrostatic forces by measuring the ion displacement. Since the heating rate is below 0.3 µeV/s, this reservoir might be used as optical detector for any ion or bunch of charged particles stored in an adjacent trap.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sci Rep Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sci Rep Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Espanha