Clinically applicable optical imaging technology for body size and shape analysis: comparison of systems differing in design.
Bourgeois, B; Ng, B K; Latimer, D; Stannard, C R; Romeo, L; Li, X; Shepherd, J A; Heymsfield, S B.
Afiliação
  • Bourgeois B; Department of Metabolism and Body Composition, Pennington Biomedical Research Center, Baton Rouge, LA, USA.
  • Ng BK; School of Electrical Engineering and Computer Science, Louisiana State University, Baton Rouge, LA, USA.
  • Latimer D; Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.
  • Stannard CR; Graduate Program in Bioengineering, University of California, Berkeley, CA, USA.
  • Romeo L; Department of Metabolism and Body Composition, Pennington Biomedical Research Center, Baton Rouge, LA, USA.
  • Li X; School of Electrical Engineering and Computer Science, Louisiana State University, Baton Rouge, LA, USA.
  • Shepherd JA; School of Electrical Engineering and Computer Science, Louisiana State University, Baton Rouge, LA, USA.
  • Heymsfield SB; School of Electrical Engineering and Computer Science, Louisiana State University, Baton Rouge, LA, USA.
Eur J Clin Nutr ; 71(11): 1329-1335, 2017 11.
Article em En | MEDLINE | ID: mdl-28876331
ABSTRACT
BACKGROUND/

OBJECTIVES:

Recent advances have extended anthropometry beyond flexible tape measurements to automated three-dimensional optical devices that rapidly acquire hundreds of body surface dimensions. Three new devices were recently introduced that share in common inexpensive optical cameras. The design, and thus potential clinical applicability, of these systems differ substantially leading us to critically evaluate their accuracy and precision. SUBJECTS/

METHODS:

113 adult subjects completed evaluations by the three optical devices (KX-16 (16 stationary cameras), Proscanner (1 vertically oscillating camera), and Styku scanner (1 stationary camera)), air displacement plethysmography (ADP), dual-energy X-ray absorptiometry (DXA) and a flexible tape measure. Optical measurements were compared to reference method estimates that included results acquired by flexible tape, DXA and ADP.

RESULTS:

Optical devices provided respective circumference and regional volume estimates that overall were well-correlated with those obtained from flexible tape measurements (for example, hip circumference R2, 0.91, 0.90, 0.96 for the KX-16, Proscanner, and Styku scanner, respectively) and DXA (for example, trunk volume R2, 0.97, 0.97, and 0.98). Total body volumes measured by the optical devices were highly correlated with those from the ADP system (all R2s, 0.99). Coefficient of variations obtained from duplicate measurements (n, 55) were larger in optical than in reference measurements and significant (P<0.05) bias was present for some optical measurements relative to reference method estimates.

CONCLUSIONS:

Overall, the evaluated optical imaging systems differing in design provided body surface measurements that compared favorably with corresponding reference methods. However, our evaluations uncovered system measurement limitations, such as discrepancies in landmarking, that with correction have the potential to improve future developed devices.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Composição Corporal / Antropometria Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Clin Nutr Assunto da revista: CIENCIAS DA NUTRICAO Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Composição Corporal / Antropometria Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Clin Nutr Assunto da revista: CIENCIAS DA NUTRICAO Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos