Your browser doesn't support javascript.
loading
Settling of virgin olive oil from horizontal screw solid bowl in static conditions.
Gila, Abraham M; Bejaoui, Mohamed A; Beltrán, Gabriel; Jiménez, Antonio.
Afiliação
  • Gila AM; IFAPA Centro "Venta del Llano", Junta de Andalucía, P.O. Box 50, 23620 Mengíbar, Jaén Spain.
  • Bejaoui MA; Fundación CITOLIVA, Centro Tecnológico del Olivar y del Aceite, Parque Científico-Técnico GEOLIT, C/Sierra Morena, manzana 11, Edif. CTSA módulo 1, 23620 Mengíbar, Jaén Spain.
  • Beltrán G; IFAPA Centro "Venta del Llano", Junta de Andalucía, P.O. Box 50, 23620 Mengíbar, Jaén Spain.
  • Jiménez A; IFAPA Centro "Venta del Llano", Junta de Andalucía, P.O. Box 50, 23620 Mengíbar, Jaén Spain.
J Food Sci Technol ; 54(9): 2989-2996, 2017 Aug.
Article em En | MEDLINE | ID: mdl-28928540
ABSTRACT
This work was aimed to study the clarification efficiency of natural decantation in settling tank on virgin olive oil obtained from a two-ways continuous process. For this purpose, the impurities content of the virgin olive oil were monitored during settling process in settling tank at two different depths. Efficiency of purging system was determined for two days. The experiments were performed at industrial scale during three crop years. During the first minutes of settling was observed an ascent of the smaller organic particles of the oil. Then, most of the virgin olive oil impurities were settled at 300 min, independently of the initial content of virgin olive oil. Finally, oil decantation showed slower rate. Higher clarification values were obtained for those decanter oils with higher impurities content, achieving clarification percentages between of 62.69 and 95.91% at 48 h of settling. The highest settling efficiency was observed for those decanter oils with initial higher impurities content. The purging system used in the settling tanks was not able to remove the most of settled impurities since a considerable amount of the impurities remained in the tank after 48 h, between 13.6 and 71.41% for the studied oils. In the tank purges was observed important oil losses. Therefore, decantation was not an efficient system for oil clarification since its settling capacity varied depending on the initial impurities content and due to the settled impurities can not be removed fully by purging system.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Food Sci Technol Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Food Sci Technol Ano de publicação: 2017 Tipo de documento: Article