Your browser doesn't support javascript.
loading
Focusing of a Rydberg Positronium Beam with an Ellipsoidal Electrostatic Mirror.
Jones, A C L; Moxom, J; Rutbeck-Goldman, H J; Osorno, K A; Cecchini, G G; Fuentes-Garcia, M; Greaves, R G; Adams, D J; Tom, H W K; Mills, A P; Leventhal, M.
Afiliação
  • Jones ACL; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Moxom J; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Rutbeck-Goldman HJ; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Osorno KA; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Cecchini GG; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Fuentes-Garcia M; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Greaves RG; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Adams DJ; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Tom HWK; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Mills AP; Department of Physics and Astronomy, University of California, Riverside, California 92521, USA.
  • Leventhal M; Department of Astronomy University of Maryland, College Park, Maryland 20742, USA.
Phys Rev Lett ; 119(5): 053201, 2017 Aug 04.
Article em En | MEDLINE | ID: mdl-28949762
ABSTRACT
Slow atoms in Rydberg states can exhibit specular reflection from a cylindrical surface upon which an azimuthally periodic potential is imposed. We have constructed a concave mirror of this type, in the shape of a truncated oblate ellipsoid of revolution, which has a focal length of (1.50±0.01) m measured optically. When placed near the center of a long vacuum pipe, this structure brings a beam of n=32 positronium (Ps) atoms to a focus on a position sensitive detector at a distance of (6.03±0.03) m from the Ps source. The intensity at the focus implies an overall reflection efficiency of ∼30%. The focal spot diameter (32±1) mm full width at half maximum is independent of the atoms' flight times from 20 to 60 µs, thus indicating that the mirror is achromatic to a good approximation. Mirrors based on this principle would be of use in a variety of experiments, allowing for improved collection efficiency and tailored transport or imaging of beams of slow Rydberg atoms and molecules.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Phys Rev Lett Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Phys Rev Lett Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos