Your browser doesn't support javascript.
loading
Chiral Plasmonic Hydrogen Sensors.
Matuschek, Marcus; Singh, Dhruv Pratap; Jeong, Hyeon-Ho; Nesterov, Maxim; Weiss, Thomas; Fischer, Peer; Neubrech, Frank; Liu, Na.
Afiliação
  • Matuschek M; Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
  • Singh DP; Kirchhoff-Institute for Physics, Im Neuenheimer Feld 227, 69120, Heidelberg, Germany.
  • Jeong HH; Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
  • Nesterov M; Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
  • Weiss T; 4th Physics Institute and Research Center SCoPE, University of Stuttgart, Pfaffenwaldring 57, 70569, Stuttgart, Germany.
  • Fischer P; 4th Physics Institute and Research Center SCoPE, University of Stuttgart, Pfaffenwaldring 57, 70569, Stuttgart, Germany.
  • Neubrech F; Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
  • Liu N; Institute for Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.
Small ; 14(7)2018 02.
Article em En | MEDLINE | ID: mdl-29266737
ABSTRACT
In this article, a chiral plasmonic hydrogen-sensing platform using palladium-based nanohelices is demonstrated. Such 3D chiral nanostructures fabricated by nanoglancing angle deposition exhibit strong circular dichroism both experimentally and theoretically. The chiroptical properties of the palladium nanohelices are altered upon hydrogen uptake and sensitively depend on the hydrogen concentration. Such properties are well suited for remote and spark-free hydrogen sensing in the flammable range. Hysteresis is reduced, when an increasing amount of gold is utilized in the palladium-gold hybrid helices. As a result, the linearity of the circular dichroism in response to hydrogen is significantly improved. The chiral plasmonic sensor scheme is of potential interest for hydrogen-sensing applications, where good linearity and high sensitivity are required.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Small Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Small Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha