Your browser doesn't support javascript.
loading
Magnetic immunoassay using CdSe/ZnS quantum dots as fluorescent probes to detect the level of DNA methyltransferase 1 in human serum sample.
Yu, Fei; Xiong, Ya-Min; Yu, Song-Cheng; He, Lei-Liang; Niu, Shan-Shan; Wu, Yu-Ming; Liu, Jie; Qu, Ling-Bo; Liu, Li-E; Wu, Yong-Jun.
Afiliação
  • Yu F; College of Public Health.
  • Xiong YM; College of Public Health.
  • Yu SC; College of Public Health.
  • He LL; College of Public Health.
  • Niu SS; College of Public Health.
  • Wu YM; College of Public Health.
  • Liu J; College of Public Health.
  • Qu LB; College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, Henan, People's Republic of China.
  • Liu LE; College of Public Health.
  • Wu YJ; College of Public Health.
Int J Nanomedicine ; 13: 429-437, 2018.
Article em En | MEDLINE | ID: mdl-29403274
BACKGROUND: DNA methyltransferase 1 (DNMT1), a dominant enzyme responsible for the transfer of a methyl group from the universal methyl donor to the 5-position of cytosine residues in DNA, is essential for mammalian development and closely related to cancer and a variety of age-related chronic diseases. DNMT1 has become a useful biomarker in early disease diagnosis and a potential therapeutic target in cancer therapy and drug development. However, till now, most of the studies on DNA methyltransferase (MTase) detection have focused on the prokaryote MTase and its activity. METHODS: A magnetic fluorescence-linked immunosorbent assay (FLISA) using CdSe/ZnS quantum dots as fluorescent probes was proposed for the rapid and sensitive detection of the DNMT1 level in this study. Key factors that affect the precision and accuracy of the determination of DNMT1 were optimized. RESULTS: Under the optimal conditions, the limit of detection was 0.1 ng/mL, the linear range was 0.1-1,500 ng/mL, the recovery was 91.67%-106.50%, and the relative standard deviations of intra- and inter-assays were respectively 5.45%-11.29% and 7.03%-11.25%. The cross-reactivity rates with DNA methyltransferases 3a and 3b were only 4.0% and 9.4%, respectively. Furthermore, FLISA was successfully used to detect the levels of DNMT1 in human serum samples, and compared with commercial enzyme-linked immunosorbent assay (ELISA) kits. The results revealed that there was a good correlation between FLISA and commercial ELISA kits (correlation coefficient r=0.866, p=0.001). The linear scope of FLISA was broader than ELISA, and the measurement time was much shorter than ELISA kits. CONCLUSION: These indicated that the proposed FLISA method was sensitive and high throughput and can quickly screen the level of DNMT1 in serum samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sulfetos / Imunoensaio / Compostos de Zinco / Compostos de Selênio / Compostos de Cádmio / Pontos Quânticos / DNA (Citosina-5-)-Metiltransferase 1 / Magnetismo Limite: Animals / Humans Idioma: En Revista: Int J Nanomedicine Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sulfetos / Imunoensaio / Compostos de Zinco / Compostos de Selênio / Compostos de Cádmio / Pontos Quânticos / DNA (Citosina-5-)-Metiltransferase 1 / Magnetismo Limite: Animals / Humans Idioma: En Revista: Int J Nanomedicine Ano de publicação: 2018 Tipo de documento: Article