Your browser doesn't support javascript.
loading
Sulfide Species Optical Monitoring by a Miniaturized Silicon Photomultiplier.
Petralia, Salvatore; Sciuto, Emanuele Luigi; Santangelo, Maria Francesca; Libertino, Sebania; Messina, Maria Anna; Conoci, Sabrina.
Afiliação
  • Petralia S; STMicroelectronics, Stradale Primosole 50, 95121 Catania, Italy. salvatore.petralia@st.com.
  • Sciuto EL; Diploma of Physics and Astronomy, University of Catania, 95100 Catania, Italy. elsciuto@unict.it.
  • Santangelo MF; CNR-IMM Sede, Strada VIII Z.I. 5, 95121 Catania, Italy. Francesca.Santangelo@imm.cnr.it.
  • Libertino S; CNR-IMM Sede, Strada VIII Z.I. 5, 95121 Catania, Italy. Sebania.Libertino@imm.cnr.it.
  • Messina MA; Azienda Policlinico Universitario, Via S. Sofia 78, 95100 Catania, Italy. mmessina@unict.it.
  • Conoci S; Centro Speleologico Etneo, Via Valdisavoia 5, 95123 Catania, Italy. mmessina@unict.it.
Sensors (Basel) ; 18(3)2018 Feb 28.
Article em En | MEDLINE | ID: mdl-29495639
ABSTRACT
The monitoring of water-soluble pollutants is receiving a growing interest from the scientific community. In this context, sulfide anion species S2- and HS- are particularly relevant since they can cause acute and chronic toxicity including neurological effects and at high concentrations, even death. In this study, a new strategy for fast and sensitive optical detection of sulfide species in water samples is described. The method uses an integrated silicon photomultiplier (SiPM) device coupled with the appropriate analytical strategy applied in a plastic microchip with dried reagents on board. More specifically, all sulfide species (H2S, HS- and S2-) in water samples are detected by the fluorescence signal emitted upon the reaction with N,N-dimethyl-phenylenediamine sulfate in the presence of Fe3+, leading to the formation of the fluorescent methylene blue (MB) species. It has been proven that the system herein proposed is able to measure sulfide concentration in a linear range from 0-10 mg L-1 with a sensitivity value of about 6.7 µA mg-1 L and a detection limit of 0.5 mg L-1. A comparison with conventional UV-Vis detection method has been also carried out. Data show a very good linear correlation (R² = 0.98093), proving the effectiveness of the method. Results pave the way toward the development of portable and low-cost device systems for water-soluble sulfide pollutants.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Itália