Your browser doesn't support javascript.
loading
Coumarin/BODIPY Hybridisation for Ratiometric Sensing of Intracellular Polarity Oscillation.
Bai, Yang; Shi, Xiangchao; Chen, Yuncong; Zhu, Chengcheng; Jiao, Yang; Han, Zhong; He, Weijiang; Guo, Zijian.
Afiliação
  • Bai Y; State Key Laboratory of Coordination Chemistry, Coordination Chemistry Institute, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, P.R. China.
  • Shi X; State Key Laboratory of Coordination Chemistry, Coordination Chemistry Institute, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, P.R. China.
  • Chen Y; State Key Laboratory of Coordination Chemistry, Coordination Chemistry Institute, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, P.R. China.
  • Zhu C; State Key Laboratory of Coordination Chemistry, Coordination Chemistry Institute, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, P.R. China.
  • Jiao Y; State Key Laboratory of Coordination Chemistry, Coordination Chemistry Institute, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, P.R. China.
  • Han Z; State Key Laboratory of Coordination Chemistry, Coordination Chemistry Institute, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, P.R. China.
  • He W; State Key Laboratory of Coordination Chemistry, Coordination Chemistry Institute, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, P.R. China.
  • Guo Z; State Key Laboratory of Coordination Chemistry, Coordination Chemistry Institute, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, P.R. China.
Chemistry ; 24(29): 7513-7524, 2018 May 23.
Article em En | MEDLINE | ID: mdl-29575108
ABSTRACT
With different polarity responses, coumarin and 4,4-difluoro-4-bora-3a,4a-diaza-s-indacene (BODIPY) were hybridised to construct polarity fluorescent sensors, CBDP and iso-CBDP, to overcome the disadvantages of solvatochromic sensors in ratiometric polarity sensing. Only CBDP displayed an emission ratio (ICou /IBDP , coumarin to BODIPY emissions) that increased with an exponential dependence on medium relative permittivity over a wide polarity range (ϵr <57.9). This sensing ability of CBDP was not affected by medium pH; viscosity; and most intracellular species, especially reactive oxygen, nitrogen, and sulfur species. Apart from local cytoplasmic polarity quantification through lambda imaging, CBDP enables real-time ratiometric imaging for intracellular polarity oscillation induced by oxidative stimulation. Ratiometric polarity flow cytometry was developed, for the first time, with CBDP, which demonstrated that a high concentration H2 O2 induced cytoplasmic polarity enhancement, whereas pre-incubation with N-acetyl-l-cysteine inhibited this effect.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Chemistry Assunto da revista: QUIMICA Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Chemistry Assunto da revista: QUIMICA Ano de publicação: 2018 Tipo de documento: Article