Ten-Year Clinical and Radiological Outcomes of 100 Total Hip Arthroplasty Cases with a Modern Cementless Dual Mobility Cup.
Laurendon, Loïc; Philippot, Rémi; Neri, Thomas; Boyer, Bertrand; Farizon, Frédéric.
Afiliação
  • Laurendon L; Service de chirurgie orthopédique, Hopital Nord, CHU Saint Etienne, France.
  • Philippot R; Service de chirurgie orthopédique, Hopital Nord, CHU Saint Etienne, France, Laboratoire Interuniversitaire de Biologie de la Motricité (LIBM), Université Claude Bernard Lyon 1, Université Jean Monnet Saint Etienne France.
  • Neri T; Service de chirurgie orthopédique, Hopital Nord, CHU Saint Etienne, France, Laboratoire Interuniversitaire de Biologie de la Motricité (LIBM), Université Claude Bernard Lyon 1, Université Jean Monnet Saint Etienne.
  • Boyer B; Service de chirurgie orthopédique, Hopital Nord, CHU Saint Etienne, France, Laboratoire Interuniversitaire de Biologie de la Motricité (LIBM), Université Claude Bernard Lyon 1, Université Jean Monnet Saint Etienne.
  • Farizon F; Service de chirurgie orthopédique, Hopital Nord, CHU Saint Etienne, France, Laboratoire Interuniversitaire de Biologie de la Motricité (LIBM), Université Claude Bernard Lyon 1, Université Jean Monnet Saint Etienne.
Surg Technol Int ; 32: 331-336, 2018 06 01.
Article em En | MEDLINE | ID: mdl-29689589
ABSTRACT

INTRODUCTION:

The original cementless Sunfit® dual mobility cup (SERF, Décines, France) exhibited limited osseointegration due to its hydroxyapatite and alumina coating. We hypothesized that replacement of the alumina with plasma-sprayed titanium + hydroxyapatite and improvement of the external geometry (Sunfit TH®) would not increase the risk of aseptic loosening. The primary goal of this study was to determine the survivorship and clinical and radiological outcomes among patients with the Sunfit TH® implant. MATERIAL AND

METHODS:

This was a single-center, prospective study of the first 100 consecutive total hip arthroplasty (THA) cases performed using the combination of a press-fit Sunfit TH® dual mobility cup and a cementless straight stem. All of the cases were primary THA and the posterolateral approach was used. The patients underwent regular clinical and radiological monitoring. Radiological measurements were carried out using OsiriX® software (Pixmeo, Geneva, Switzerland).

RESULTS:

As of the final follow-up, 19 patients had died and 4 could not be contacted. Of the remaining patients, there were zero cases of aseptic loosening, dislocation or intraprosthetic dislocation (IPD). The survivorship was 100% at 10.03 years of follow-up. No significant implant migration was measured on radiographs.

CONCLUSION:

The excellent long-term outcomes with the Sunfit TH® cup are likely due to the use of plasma-sprayed titanium + hydroxyapatite in the coating and the addition of supplementary ridges and grooves to the outside of the cup. The absence of aseptic loosening, dislocation and IPD further confirms the high stability and good survivorship that can be achieved with these implants. We believe dual mobility cups should be used in patients above 60 years of age and in those below 60 years of age with a high risk of postoperative instability.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Artroplastia de Quadril Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Surg Technol Int Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Artroplastia de Quadril Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Surg Technol Int Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França