ABSTRACT

Objective:

By evaluating the hemodynamic parameters such as cardiac output (CO), right ventricular pressure (RVP), pulmonary artery pressure (PAP) and total pulmonary resistance index (TPRI) in pulmonary hypertension rat model, we established a more comprehensive hemodynamic evaluation system, which objectively evaluated the severity of disease and exercise tolerance in rats with pulmonary hypertension.

Methods:

SD rats were randomly divided into a control group and a model group with 5 rats in each group. The model group was intraperitoneally injected with SU5416 (20 mg/kg) and placed in an oxygen chamber at a 10% oxygen concentration for 21 days and then placed in a normoxic environment for 14 days. After modeling, rats were anesthetized and mechanically ventilated. The operator cut the skin along the right paraxial line, detached and ligated the intercostal artery, and then cut off the 3 and 4 ribs, exposing the heart and freeing aortic root about 0.2 cm. The flowmeter probe was set in the dissected aortic segment, and real-time recording time, blood flow waveforms, cardiac output were calculated accordingly. Then the needle attached to the baroreceptor was inserted into the right ventricle and the system acquired the right ventricular time-pressure waveform. After the waveform stabilized for about 30 seconds, the end of the cannula was sent to the pulmonary artery trunk through the entrance of the pulmonary artery to record the time-pressure curve of the pulmonary artery.

Results:

RVSP, PASP, PADP and mPAP in the model group were significantly higher than those of the control group [ RVSP(23.4±5.4) mmHg, 1 mmHg=0.133 kPa vs (56.4±13.0) mmHg, PASP (22.8±4.4) mmHg vs (58.5±14.9) mmHg, PADP (9.7±1.9) mmHg vs (30.3±7.0) mmHg, mPAP (14.1±2.7) mmHg vs (41.9±8.0) mmHg, all P<0.05 ]. Compared with the control group, the cardiac index in the model group was significantly lower [ CI (0.54±0.08) ml·min(-1)·g(-1) vs (0.40±0.09) ml·min(-1)·g(-1,) P=0.02 ]. Furthermore, compared with the control group, pulmonary vascular resistance index was significantly increased in the model group[PVRI (0.27±0.03) mmHg·ml(-1)·min(-1)·kg(-1) vs (0.06±0.01) mmHg·ml(-1)·min(-1)·kg(-1,) P<0.05]. The pathological results also showed that the middle part of pulmonary arterioles in the model group had muscular hypertrophy and muscular pulmonary arterioles, and even plexiform lesions.

Conclusion:

In this study, we established a new method that simultaneously determined several hemodynamic parameters such as RVSP, PASP, PADP, CO, CI and PVRI, which provided a more comprehensive assessment of hemodynamic changes in pulmonary hypertension rat models.