Your browser doesn't support javascript.
loading
Differences in myoelectric manifestations of fatigue during isometric muscle actions.
Gawda, Piotr; Ginszt, Michal; Ginszt, Apolinary; Pawlak, Halina; Majcher, Piotr.
Afiliação
  • Gawda P; Medical Univesity of Lublin, Poland. piotr.gawda@umlub.pl.
  • Ginszt M; Medical Univesity of Lublin, Poland. michal.ginszt@umlub.pl.
  • Ginszt A; Medical Univesity of Lublin, Poland. apolinary.ginszt@umlub.pl.
  • Pawlak H; University of Life Sciences in Lublin, Poland. halina.pawlak@up.lublin.pl.
  • Majcher P; Medical Univesity of Lublin, Poland. piotr.majcher@umlub.pl.
Ann Agric Environ Med ; 25(2): 296-299, 2018 Jun 20.
Article em En | MEDLINE | ID: mdl-29936808
INTRODUCTION: Muscle fatigue has been studied for a long time with the use of a wide variety of exercise models, protocols and assessment methods, among which surface electromyography (sEMG) is most commonly used. The main sEMG parameters (amplitude and frequency) are prevalently used to evaluate the level of muscle fatigue in static and dynamic contractions. OBJECTIVE: The purpose of this study is to determine and compare 2 separate indices: IF1 basis of the sEMG signal amplitude analysis and IF2 basis of the sEMG median frequency analysis, related to muscles fatigue during an isometric contraction. MATERIAL AND METHODS: The study was performed on 60 professional runners divided into 2 equal groups. The first group comprised sprinters, competing in short distance track and field events (100 and 200 meters). The second group consisted of middle-distance runners, competing in middle-distance track and field events (800 and 1,500 meters). The electrical activity of the VMO muscles of the right and left lower limbs was recorded simultaneously during isometric activity in a squatting position. The sEMG data was used to determine and compare IF1 and IF2 indices. RESULTS: During isometric measurement, sprinters presented a much more significant increase in the mean amplitude of sEMG signal in comparison to middle-distance runners (mean IF1 difference: 0.228; p=0.007). Analysis of the median frequency did not show significant differences between the 2 groups (mean IF2 difference: 0.037; p=0.12). CONCLUSIONS: Change in sEMG amplitude during isometric exercise may be related to muscles fatigue. The use of fatigue indices, based on sEMG amplitude, as an objective indicator of the efficacy of an endurance training programme for sportsmen requires further research.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corrida / Músculo Esquelético / Fadiga Muscular / Contração Isométrica Limite: Adolescent / Adult / Humans / Male Idioma: En Revista: Ann Agric Environ Med Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corrida / Músculo Esquelético / Fadiga Muscular / Contração Isométrica Limite: Adolescent / Adult / Humans / Male Idioma: En Revista: Ann Agric Environ Med Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Polônia