Your browser doesn't support javascript.
loading
Valvuloplasty balloon entrapment in a self-expanding aortic valve stent frame after inadvertent wire passage through the outflow struts.
Piayda, Kerstin; Hellhammer, Katharina; Veulemans, Verena; Zeus, Tobias.
Afiliação
  • Piayda K; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Hellhammer K; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Veulemans V; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Zeus T; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
Catheter Cardiovasc Interv ; 93(1): 174-177, 2019 01 01.
Article em En | MEDLINE | ID: mdl-30244518
ABSTRACT
Transcatheter aortic valve replacement (TAVR) is a leading-edge therapy option for patients with severe aortic stenosis (AS) and high surgical risk. However, this minimally invasive procedure is associated with specific complications that may be life-threatening. Valvuloplasty balloon entrapment during postdilatation in transcatheter self-expanding aortic valve stent frames has not yet been a focus of interest in this context. Although it is a rare event, it may critically influence outcome, and different management strategies can be considered. Hereafter, we present the case of a 67-year-old male who underwent transfemoral TAVR and subsequent postdilatation. The valvuloplasty balloon was entrapped in the self-expanding aortic valve stent frame after inadvertent wire passage through the outflow struts. Since surgical risk was high, we preferred a percutaneous approach and extracted the entrapped balloon with high traction force under rapid pacing after valve stabilization with another balloon, which was placed in the annular position.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Valvuloplastia com Balão / Cateteres Cardíacos / Substituição da Valva Aórtica Transcateter Limite: Aged / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Valvuloplastia com Balão / Cateteres Cardíacos / Substituição da Valva Aórtica Transcateter Limite: Aged / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha