Correlation of peripapillary retinal nerve fibre layer thickness with visual acuity in paediatric patients affected by optic pathway glioma.
Acta Ophthalmol
; 96(8): e1004-e1009, 2018 Dec.
Article
em En
| MEDLINE
| ID: mdl-30284379
ABSTRACT
PURPOSE:
To evaluate peripapillary retinal nerve fibre layer (RNFL) thickness, measured by spectral-domain optical coherence tomography (SD-OCT), as a surrogate of visual function in a population of paediatric patients affected by optic pathway glioma (OPG) associated with neurofibromatosis type 1 (NF1).METHODS:
A total of 38 paediatric patients (66 eyes) affected by MRI-proven OPG were included. Each patient underwent complete ophthalmological examination, including age-appropriate visual acuity (VA) assessment and RNFL analysis by SD-OCT. Visual acuity was classified as normal or pathologic using age-based normative data. Visual acuity was correlated to mean RNFL thickness of the whole peripapillary area and of each single analyzed sector (nasal, superior, temporal, inferior).RESULTS:
Visual acuity was normal in 43 (65%) and pathologic in 23 (35%) eyes. Mean parapapillary RNFL thickness of each analyzed sector was significantly lower in eyes with abnormal VA (p < 0.05). The best balanced cut-off value of global RNFL thickness allowing to discriminate between eyes with normal and pathologic VA was 76.25 µm (91%, 76%, 67% and 94% of sensitivity, specificity, positive and negative predicting value, respectively). Considering best balanced cut-off values of other analyzed RNFL sectors, the superior (p = 0.0029) and the inferior (p = 0.0024) sectors reached the higher sensitivity (87% and 87%, respectively) and specificity (81% and 79%, respectively).CONCLUSION:
Retinal nerve fibre layer thickness is directly related to VA in children affected by NF1-related OPG, and should be considered as a potential surrogate marker of VA. Retinal nerve fibre layer thickness cut-off values can be used in paediatric patients to discriminate false-positive results obtained by VA measurement.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Disco Óptico
/
Células Ganglionares da Retina
/
Acuidade Visual
/
Glioma do Nervo Óptico
/
Tomografia de Coerência Óptica
/
Fibras Nervosas
Tipo de estudo:
Clinical_trials
/
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Adolescent
/
Child
/
Child, preschool
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Acta Ophthalmol
Assunto da revista:
OFTALMOLOGIA
Ano de publicação:
2018
Tipo de documento:
Article
País de afiliação:
Itália