Instrumentation for the upgrade to the JET core charge-exchange spectrometers.
Hawkes, N C; Delabie, E; Menmuir, S; Giroud, C; Meigs, A G; Conway, N J; Biewer, T M; Hillis, D L.
Afiliação
  • Hawkes NC; UKAEA/CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Delabie E; Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6169, USA.
  • Menmuir S; UKAEA/CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Giroud C; UKAEA/CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Meigs AG; UKAEA/CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Conway NJ; UKAEA/CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Biewer TM; Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6169, USA.
  • Hillis DL; Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6169, USA.
Rev Sci Instrum ; 89(10): 10D113, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30399852
ABSTRACT
Charge-exchange spectroscopy on JET has become particularly challenging with the introduction of the ITER-like wall. The line intensities are weaker and contaminated by many nuisance lines. We have therefore upgraded the instrumentation to improve throughput and allow the simultaneous measurement of impurity and fuel-ion charge exchange by splitting the light between two pairs of imaging spectrometers using dichroic beam splitters. Imaging instruments allow us to stack 11 × 1 mm diameter fibres on the entrance slits without cross talk. CCD cameras were chosen to have 512 × 512 pixels to allow frame transfer times <0.2 ms which with minimum exposure times of 5 ms give tolerable smearing even without a chopper. The image plane is optically demagnified 21 to match the sensor size of these cameras. Because the image plane of the spectrometer is tilted, the CCD must also be tilted to maintain focus over the spectrum (Scheimpflug condition). To avoid transverse keystoning (causing the vertical height of the spectra to change across the sensor), the configuration is furthermore designed to be telecentric by a suitable choice of the lens separation. The lens configuration is built almost entirely from commercial off-the-shelf components, which allowed it to be assembled and aligned relatively rapidly to meet the deadline for in-vessel calibration in the JET shutdown.