Disposable Paper-Based Analytical Device for Visual Speciation Analysis of Ag(I) and Silver Nanoparticles (AgNPs).
Liu, Qinlei; Lin, Yao; Xiong, Jing; Wu, Li; Hou, Xiandeng; Xu, Kailai; Zheng, Chengbin.
Afiliação
  • Liu Q; Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry , Sichuan University , Chengdu , Sichuan 610064 , China.
  • Lin Y; Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry , Sichuan University , Chengdu , Sichuan 610064 , China.
  • Xiong J; Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry , Sichuan University , Chengdu , Sichuan 610064 , China.
  • Wu L; Analytical & Testing Center , Sichuan University , Chengdu , Sichuan 610064 , China.
  • Hou X; Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry , Sichuan University , Chengdu , Sichuan 610064 , China.
  • Xu K; Analytical & Testing Center , Sichuan University , Chengdu , Sichuan 610064 , China.
  • Zheng C; Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry , Sichuan University , Chengdu , Sichuan 610064 , China.
Anal Chem ; 91(5): 3359-3366, 2019 03 05.
Article em En | MEDLINE | ID: mdl-30688069
A disposable, instrument-free, height readout paper-based analytical device (HR-PAD) based on a paper strip inkjet-printed with CdTe quantum dots (QDs) was developed for the sensitive speciation analysis of Ag+ and silver nanoparticles (AgNPs). When the paper strip is immersed into a sample solution, capillary action draws it through the surface and any Ag+ in the solution quenches the fluorescence of CdTe QDs via a cation exchange reaction between Ag+ and the CdTe QDs, with the height of the quenched band being proportional to the concentration of Ag+. In contrast, fluorescence quenching cannot be observed when only AgNPs are present in solution. Thus, the concentration of AgNPs can be obtained by subtracting the Ag+ content from the total silver determined by the HR-PAD after digestion with HNO3. Under optimized conditions, the methodology provides high selectivity, sensitivity, and accuracy for the detection of Ag+ or AgNPs in various samples, even at concentrations as low as 0.05 mg L-1. Precisions of 4.5% and 2.2% RSDs were achieved at concentrations of 1 mg L-1 and 7 mg L-1 of Ag+, respectively. Compared to conventional methods, this approach is inexpensive and user-friendly and eliminates the need for expensive and sophisticated detection instruments. The practicality of the method was demonstrated via the speciation analysis of AgNPs and Ag+ in river water and 12 commercial products with satisfactory results.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China