Your browser doesn't support javascript.
loading
A volumetric absorptive microsampling LC-MS/MS method for five immunosuppressants and their hematocrit effects.
Koster, Remco A; Niemeijer, Pascal; Veenhof, Herman; Hateren, Kai van; Alffenaar, Jan-Willem C; Touw, Daan J.
Afiliação
  • Koster RA; Department of Clinical Pharmacy & Pharmacology, University of Groningen, University Medical Center Groningen,  Groningen, The Netherlands.
  • Niemeijer P; Bioanalytical Laboratory, PRA Health Sciences, Amerikaweg 18, 9407 TK, Assen, The Netherlands.
  • Veenhof H; Department of Clinical Pharmacy & Pharmacology, University of Groningen, University Medical Center Groningen,  Groningen, The Netherlands.
  • Hateren KV; Bioanalytical Laboratory, PRA Health Sciences, Amerikaweg 18, 9407 TK, Assen, The Netherlands.
  • Alffenaar JC; Department of Clinical Pharmacy & Pharmacology, University of Groningen, University Medical Center Groningen,  Groningen, The Netherlands.
  • Touw DJ; Department of Clinical Pharmacy & Pharmacology, University of Groningen, University Medical Center Groningen,  Groningen, The Netherlands.
Bioanalysis ; 11(6): 495-508, 2019 Mar.
Article em En | MEDLINE | ID: mdl-30892068
ABSTRACT

Aim:

The aim of this study was to develop and validate a LC-MS/MS assay for tacrolimus, sirolimus, everolimus, cyclosporin A and mycophenolic acid using volumetric absorptive microsampling tips as a sampling device and to investigate the effect on the recoveries of the analyte concentration in combination with the hematocrit (HT), which included temsirolimus (a structural analog).

Results:

The maximum observed overall bias was 9.6% for the sirolimus LLOQ, while the maximum overall coefficient of variation was 8.3% for the everolimus LLOQ. All five immunosuppressants demonstrated to be stable in the volumetic absorbtive microsampling tips for at least 14 days at 25°C. Biases caused by HT effects were within 15% for all immunosuppressants between HT levels of 0.20 and 0.60 l/l, except for cyclosporin A, which was valid between 0.27 and 0.60 l/l. Reduced recoveries were observed at high analyte concentrations in combination with low HT values for sirolimus, everolimus and temsirolimus.

Conclusion:

A robust extraction and analysis method in volumetric absorptive microsampling tips was developed and fully validated. HT- and concentration-related recovery effects were observed but were within requirements of the purpose of the analytical method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunossupressores Limite: Humans Idioma: En Revista: Bioanalysis Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunossupressores Limite: Humans Idioma: En Revista: Bioanalysis Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Holanda