Thin, Very Thin, or Ultrathin Strut Biodegradable or Durable Polymer-Coated Drug-Eluting Stents: 3-Year Outcomes of BIO-RESORT.
Buiten, Rosaly A; Ploumen, Eline H; Zocca, Paolo; Doggen, Carine J M; Danse, Peter W; Schotborgh, Carl E; Scholte, Martijn; van Houwelingen, K Gert; Stoel, Martin G; Hartmann, Marc; Tjon Joe Gin, R Melvyn; Somi, Samer; Linssen, Gerard C M; Kok, Marlies M; von Birgelen, Clemens.
Afiliação
  • Buiten RA; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands; Department of Health Technology and Services Research, Faculty BMS, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
  • Ploumen EH; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands; Department of Health Technology and Services Research, Faculty BMS, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
  • Zocca P; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands; Department of Health Technology and Services Research, Faculty BMS, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
  • Doggen CJM; Department of Health Technology and Services Research, Faculty BMS, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
  • Danse PW; Department of Cardiology, Rijnstate Hospital, Arnhem, the Netherlands.
  • Schotborgh CE; Department of Cardiology, Haga Hospital, The Hague, the Netherlands.
  • Scholte M; Department of Cardiology, Albert Schweitzer Hospital, Dordrecht, the Netherlands.
  • van Houwelingen KG; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
  • Stoel MG; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
  • Hartmann M; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
  • Tjon Joe Gin RM; Department of Cardiology, Rijnstate Hospital, Arnhem, the Netherlands.
  • Somi S; Department of Cardiology, Haga Hospital, The Hague, the Netherlands.
  • Linssen GCM; Department of Cardiology, Hospital Group Twente, Almelo and Hengelo, the Netherlands.
  • Kok MM; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands; Department of Health Technology and Services Research, Faculty BMS, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
  • von Birgelen C; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands; Department of Health Technology and Services Research, Faculty BMS, Technical Medical Centre, University of Twente, Enschede, the Netherlands. Electronic address: c.vonbirgelen@mst.nl.
JACC Cardiovasc Interv ; 12(17): 1650-1660, 2019 09 09.
Article em En | MEDLINE | ID: mdl-31422087
ABSTRACT

OBJECTIVES:

The aim of this study was to assess the 3-year safety and efficacy of treating all-comer patients with 3 contemporary drug-eluting stents (DES).

BACKGROUND:

The BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) (TWENTE III) randomized trial (NCT01674803) found similar 1-year safety and efficacy for the 2 biodegradable-polymer DES (i.e., ultrathin-strut cobalt-chromium Orsiro sirolimus-eluting stent [SES] and very-thin-strut platinum-chromium Synergy everolimus-eluting stent) compared with the durable-polymer thin-strut cobalt-chromium Resolute Integrity zotarolimus-eluting stent (ZES). Two-year follow-up suggested that the SES might reduce repeat revascularizations beyond 1 year compared with the ZES.

METHODS:

A total of 3,514 all-comer patients were treated at 4 centers for coronary intervention. The main clinical endpoint, target vessel failure, was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularization). Secondary endpoints included the individual components of target vessel failure and stent thrombosis.

RESULTS:

Three-year follow-up data were available for 3,393 of 3,514 patients (96.6%). Target vessel failure occurred in 8.5% with SES and 10.0% with ZES (plog rank = 0.22) and in 8.8% with everolimus-eluting stents (vs. ZES, plog rank = 0.32). Rates of cardiac death, target vessel myocardial infarction, and target vessel revascularization were similar between stent groups. Landmark analyses found no statistically significant between-stent difference in repeat revascularization between 1 and 3 years. Definite or probable stent thrombosis rates were low (SES, 1.1%; everolimus-eluting stent, 1.1%; ZES, 0.9%) and similar with all 3 DES.

CONCLUSIONS:

Despite substantial differences in stent backbone and polymer coating, all 3 DES showed favorable 3-year safety and efficacy in all comers, without significant between-stent differences. Further follow-up is required to definitely answer the question of whether one stent might improve clinical outcomes at a later stage.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Doença da Artéria Coronariana / Fármacos Cardiovasculares / Sirolimo / Implantes Absorvíveis / Stents Farmacológicos / Intervenção Coronária Percutânea / Everolimo Tipo de estudo: Clinical_trials / Etiology_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: JACC Cardiovasc Interv Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Doença da Artéria Coronariana / Fármacos Cardiovasculares / Sirolimo / Implantes Absorvíveis / Stents Farmacológicos / Intervenção Coronária Percutânea / Everolimo Tipo de estudo: Clinical_trials / Etiology_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: JACC Cardiovasc Interv Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Holanda