Your browser doesn't support javascript.
loading
A new and simplified comprehensive ultrasound protocol of haemophilic joints: the Universal Simplified Ultrasound (US-US) protocol.
Kandagaddala, M; Sundaramoorthy, M; Keshava, S N; Gibikote, S; Mahata, K M; Kavitha, M L; Poonnoose, P; Srivastava, A.
Afiliação
  • Kandagaddala M; Radiology, Christian Medical College, Vellore, India.
  • Sundaramoorthy M; Radiology, Christian Medical College, Vellore, India.
  • Keshava SN; Radiology, Christian Medical College, Vellore, India. Electronic address: aparna_shyam@yahoo.com.
  • Gibikote S; Radiology, Christian Medical College, Vellore, India.
  • Mahata KM; Radiology, Christian Medical College, Vellore, India.
  • Kavitha ML; Haematology, Christian Medical College, Vellore, India.
  • Poonnoose P; Orthopaedics, Christian Medical College, Vellore, India.
  • Srivastava A; Haematology, Christian Medical College, Vellore, India.
Clin Radiol ; 74(11): 897.e9-897.e16, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31474302
ABSTRACT

AIM:

To present a new protocol to optimise ultrasound (US) assessment of haemophilic arthropathy. MATERIALS AND

METHODS:

Ultrasound of haemophilic arthropathy joints was performed using three different ultrasound protocols, namely, the Toronto-Vellore Comprehensive Ultrasound (TVC-US) protocol, the Haemophilia Early Arthropathy Detection with Ultrasound (HEAD-US), and the newly developed Universal Simplified Ultrasound (US-US) protocol. Synovial hypertrophy, haemosiderin deposition, effusion, erosion, and cartilage loss were evaluated in 20 joints. The reliability and diagnostic efficiency of these protocols was compared using magnetic resonance imaging (MRI).

RESULTS:

The correlation between the TVC-US and US-US protocols for synovial hypertrophy was excellent kappa significance (KS) was 1, but was substantial (KS=0.65) with the HEAD-US protocol. For effusion, both the TVC-US and the HEAD-US protocols had substantial correlation with the US-US protocol (KS=0.7 and 0.6 respectively). The correlation for erosion and cartilage loss was excellent between the TVC-US and the US-US with MRI (KS=1), but poor (KS=0) with the HEAD-US protocol. The US-US protocol also had good interobserver agreement (KS=1).

CONCLUSION:

The accuracy of the US-US protocol is comparable to the TVC-US protocol and MRI and is superior to the HEAD-US protocol in the assessment of haemophilic arthropathy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disco da Articulação Temporomandibular / Hemofilia A / Articulação do Joelho / Articulação do Tornozelo Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Child / Humans Idioma: En Revista: Clin Radiol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disco da Articulação Temporomandibular / Hemofilia A / Articulação do Joelho / Articulação do Tornozelo Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Child / Humans Idioma: En Revista: Clin Radiol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Índia