Your browser doesn't support javascript.
loading
Screening 89 Pesticides in Fishery Drugs by Ultrahigh Performance Liquid Chromatography Tandem Quadrupole-Orbitrap Mass Spectrometer.
Wang, Shou-Ying; Kong, Cong; Chen, Qing-Ping; Yu, Hui-Juan.
Afiliação
  • Wang SY; Laboratory of Quality & Safety Risk Assessment for Aquatic products (Shanghai), Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Shanghai 200090, China. magnolia7319@163.com.
  • Kong C; College of Food Science & Technology, Shanghai Ocean University, Shanghai 201306, China. magnolia7319@163.com.
  • Chen QP; Laboratory of Quality & Safety Risk Assessment for Aquatic products (Shanghai), Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Shanghai 200090, China. kongcong@gmail.com.
  • Yu HJ; Key Laboratory of East China Sea Fishery Resources Exploitation, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, China. kongcong@gmail.com.
Molecules ; 24(18)2019 Sep 17.
Article em En | MEDLINE | ID: mdl-31533222
ABSTRACT
Multiclass screening of drugs with high resolution mass spectrometry is of great interest due to its high time-efficiency and excellent accuracy. A high-scale, fast screening method for pesticides in fishery drugs was established based on ultrahigh performance liquid chromatography tandem quadrupole-Orbitrap high-resolution mass spectrometer. The target compounds - were diluted in methanol and extracted by ultrasonic treatment, and the extracts were diluted with MeOH-water (11, v/v) and centrifuged to remove impurities. The chromatographic separation was performed on an Accucore aQ-MS column (100 mm × 2.1 mm, 2.6 µm) with gradient elution using 0.1% formic acid in water (containing 5 mmol/L ammonium formate) and 0.1% formic acid in methanol (containing 5 mmol/L ammonium formate) in Full Scan/dd-MS2 (TopN) scan mode. A screening database, including mass spectrometric and chromatographic information, was established for identification of compounds. The screening detection limits of methods ranged between 1-500 mg/kg, the recoveries of real samples spiked with the concentration of 10 mg/kg and 100 mg/kg standard mixture ranged from 70% to 110% for more than sixty compounds, and the relative standard deviations (RSDs) were less than 20%. The application of this method showed that target pesticides were screened out in 10 samples out of 21 practical samples, in which the banned pesticide chlorpyrifos were detected in 3 out of the 10 samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas / Contaminação de Alimentos / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Peixes Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Animals Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas / Contaminação de Alimentos / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Peixes Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Animals Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China