Your browser doesn't support javascript.
loading
MRI method for labeling and imaging decellularized extracellular matrix scaffolds for tissue engineering.
Szulc, Daniel Andrzej; Ahmadipour, Mohammadali; Aoki, Fabio Gava; Waddell, Thomas K; Karoubi, Golnaz; Cheng, Hai-Ling Margaret.
Afiliação
  • Szulc DA; Institute of Biomaterials & Biomedical Engineering, University of Toronto, Canada.
  • Ahmadipour M; Ted Rogers Centre for Heart Research, Translational Biology & Engineering Program, Toronto, Canada.
  • Aoki FG; Institute of Biomaterials & Biomedical Engineering, University of Toronto, Canada.
  • Waddell TK; Latner Thoracic Surgery Laboratories, Toronto General Hospital Research Institute, University Health Network, Toronto, Canada.
  • Karoubi G; Latner Thoracic Surgery Laboratories, Toronto General Hospital Research Institute, University Health Network, Toronto, Canada.
  • Cheng HM; Institute of Biomaterials & Biomedical Engineering, University of Toronto, Canada.
Magn Reson Med ; 83(6): 2138-2149, 2020 06.
Article em En | MEDLINE | ID: mdl-31729091
ABSTRACT

PURPOSE:

To develop a facile method for labeling and imaging decellularized extracellular matrix (dECM) scaffolds intended for regenerating 3D tissues.

METHODS:

A small molecule manganese porphyrin, MnPNH2 , was synthesized and used to label dECM scaffolds made from porcine bladder and trachea and murine whole lungs. The labeling protocol was optimized on bladder dECM, and imaging on a 3T clinical scanner was performed to assess reductions in T1 and T2 relaxation times. In vivo MRI was performed on dECM injected in the rat dorsum to verify sensitivity of detection. Toxicity assays for cell viability, metabolism, and proliferation were performed on human umbilical vein endothelial cells. The incorporation of MnPNH2 and its long-term retention in dECM were assessed on transmission electron microscopy and ultraviolet absorbance of eluted MnPNH2 over time.

RESULTS:

All tissues, including thick whole 3D organs, were uniformly labeled and demonstrated high signal-to-noise on MRI. A nearly 10-fold reduction in T1 was consistently obtained at a labeling dose of 0.4 mM, and even 0.2 mM provided sufficient contrast in vivo and ex vivo. No toxicity was observed up to 0.4 mM, the maximum tested. Binding studies suggested nonspecific association, and retention studies in the labeled whole decellularized lungs revealed less than 20% MnPNH2 loss over 30 days, the majority occurring in the first 3 days after labeling.

CONCLUSION:

The proposed labeling method is the first report for visualizing dECM on MRI and has the potential for long-term monitoring and optimization of dECM-based organ tissue engineering.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Engenharia Tecidual / Matriz Extracelular Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Engenharia Tecidual / Matriz Extracelular Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá