Your browser doesn't support javascript.
loading
Bioresorbable scaffold implantation in STEMI patients: 5 years imaging subanalysis of PRAGUE-19 study.
Kocka, Viktor; Tousek, Petr; Kozel, Martin; Buono, Andrea; Hajsl, Martin; Lisa, Libor; Budesínský, Tomás; Malý, Martin; Widimský, Petr.
Afiliação
  • Kocka V; Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovské Vinohrady, Srobárova 50, Prague 10, 100 34, Czech Republic.
  • Tousek P; Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovské Vinohrady, Srobárova 50, Prague 10, 100 34, Czech Republic. tousek@email.cz.
  • Kozel M; Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovské Vinohrady, Srobárova 50, Prague 10, 100 34, Czech Republic.
  • Buono A; Department of Cardiology, Niguarda Ca' Granda Hospital, Milan, Italy.
  • Hajsl M; Cardiovascular Center, First Faculty of Medicine, Charles University and Central Military Hospital Prague, Prague, Czech Republic.
  • Lisa L; Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovské Vinohrady, Srobárova 50, Prague 10, 100 34, Czech Republic.
  • Budesínský T; Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovské Vinohrady, Srobárova 50, Prague 10, 100 34, Czech Republic.
  • Malý M; Cardiovascular Center, First Faculty of Medicine, Charles University and Central Military Hospital Prague, Prague, Czech Republic.
  • Widimský P; Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovské Vinohrady, Srobárova 50, Prague 10, 100 34, Czech Republic.
J Transl Med ; 18(1): 33, 2020 01 30.
Article em En | MEDLINE | ID: mdl-32000796
BACKGROUND: Bioresorbable scaffold (BRS) Absorb™ clinical use has been stopped due to higher rate of device thrombosis. Scaffold struts persist longer than 2 years in the vessel wall. Second generation devices are being developed. This study evaluates long-term invasive imaging in STEMI patients. METHODS: PRAGUE-19 study is an academic study enrolling consecutive STEMI patients with intention to implant Absorb™ BRS. A total of 83 STEMI patients between December 2012 and March 2014 fulfilled entry criteria. Coronary angiography and optical coherence tomography at 5 year follow-up was performed in 25 patients. RESULTS: Primary combined clinical endpoint (death, myocardial infarction or target vessel revascularization) occurred in 12.6% during the five-year follow-up with overall mortality 6.3%. Definite scaffold thrombosis occurred in 2 patients in the early phase after BRS implantation. Quantitative coronary angiography after 5 years demonstrated low late lumen loss of 0.11 ± 0.35 mm with binary restenosis rate of 0%. Optical coherence tomography demonstrated complete resorption of scaffold struts and mean lumen diameter of 3.25 ± 0.30 and 3.22 ± 0.49 (P = 0.73) at baseline and after 5 years, respectively. Three patients developed small coronary artery aneurysm in the treated segment. CONCLUSION: Invasive imaging results 5 years after BRS implantation in STEMI showed complete resorption of scaffold struts and stable lumen vessel diameter. Trial registration ISRCTN43696201 (retrospectivelly registred, June 7th, 2019). https://www.isrctn.com/ISRCTN43696201.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Stents Farmacológicos / Intervenção Coronária Percutânea / Infarto do Miocárdio com Supradesnível do Segmento ST Limite: Humans Idioma: En Revista: J Transl Med Ano de publicação: 2020 Tipo de documento: Article País de afiliação: República Tcheca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Stents Farmacológicos / Intervenção Coronária Percutânea / Infarto do Miocárdio com Supradesnível do Segmento ST Limite: Humans Idioma: En Revista: J Transl Med Ano de publicação: 2020 Tipo de documento: Article País de afiliação: República Tcheca