Your browser doesn't support javascript.
loading
Spectral unmixing applied to fast identification of γ-emitting radionuclides using NaI(Tl) detectors.
Paradis, H; Bobin, C; Bobin, J; Bouchard, J; Lourenço, V; Thiam, C; André, R; Ferreux, L; de Vismes Ott, A; Thévenin, M.
Afiliação
  • Paradis H; CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France.
  • Bobin C; CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France. Electronic address: christophe.bobin@cea.fr.
  • Bobin J; CEA, IRFU, Laboratoire de cosmologie et statistiques, 91191, Gif-sur-Yvette Cedex, France.
  • Bouchard J; CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France.
  • Lourenço V; CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France.
  • Thiam C; CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France.
  • André R; CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France.
  • Ferreux L; IRSN, Laboratoire de mesures Nucléaires, 78116, Le Vésinet Cedex, France.
  • de Vismes Ott A; IRSN, Laboratoire de métrologie de la radioactivité dans l'environnement, 91400, Orsay, France.
  • Thévenin M; CEA, IRAMIS, Service de physique de l'état condensé, 91191, Gif-sur-Yvette Cedex, France.
Appl Radiat Isot ; 158: 109068, 2020 Apr.
Article em En | MEDLINE | ID: mdl-32174369
ABSTRACT
Spectral unmixing was investigated for fast spectroscopic identification in γ-emitter mixtures at low-statistics in the case of measurements performed to prevent illegal nuclear material trafficking or for in situ environmental analysis following a radiological or nuclear accident. For that purpose, a multiplicative update algorithm based on full-spectrum analysis was tested in the case of a 3″x3″ NaI(Tl) detector. Automatic decision-making was addressed using Monte Carlo calculations of decision thresholds and detection limits. The first results obtained with a portable instrument equipped with a 3″x3″ NaI(Tl) detector designed for the control of food samples by non-expert users following a radiological or nuclear accident, are also presented.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2020 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2020 Tipo de documento: Article País de afiliação: França