Your browser doesn't support javascript.
loading
Dual-energy CT to differentiate gallbladder polyps: cholesterol versus adenomatous.
Yin, Sheng Nan; Chi, Jing; Liu, Li; Ding, Ning; Ji, Yi Ding; Yuan, Jian Mao.
Afiliação
  • Yin SN; Department of Medical Imaging, Suzhou Ninth People's Hospital, Wujiang, Jiangsu, PR China.
  • Chi J; Department of Medical Imaging, Suzhou Ninth People's Hospital, Wujiang, Jiangsu, PR China.
  • Liu L; Department of Medical Imaging, Suzhou Ninth People's Hospital, Wujiang, Jiangsu, PR China.
  • Ding N; Department of Medical Imaging, Suzhou Ninth People's Hospital, Wujiang, Jiangsu, PR China.
  • Ji YD; Department of Medical Imaging, Suzhou Ninth People's Hospital, Wujiang, Jiangsu, PR China.
  • Yuan JM; Department of Medical Imaging, Suzhou Ninth People's Hospital, Wujiang, Jiangsu, PR China.
Acta Radiol ; 62(2): 147-154, 2021 Feb.
Article em En | MEDLINE | ID: mdl-32295387
BACKGROUND: Dual-energy computed tomography (DE-CT) scans were acquired to identify cholesterol and adenomatous gallbladder (GB) polyps, which have not been well evaluated before surgery. PURPOSE: To evaluate the DE-CT findings of GB polyps 1.0-2.0 cm in size and differentiate between cholesterol and adenomatous polyps. MATERIAL AND METHODS: Forty-six patients with GB polyps were surgically treated from December 2017 to December 2019 and divided into two groups according to their postoperative pathologic results: a cholesterol group with 26 patients and an adenomatous group with 20 patients. All of these patients underwent DE-CT imaging with tube voltages of 80 kVp and 140 kVp within two weeks before surgery. Mean attenuation values were measured for every GB polyp at 80/140 kVp and at 40/140 keV. The mean attenuation value changes between 140 kVp and 80 kVp (MAVC140-80 kVp) and mean attenuation value changes between 100 keV and 40 keV (MAVC100-40 keV) were calculated. RESULTS: The CT image parameters of all 46 patients with GB polyps were analyzed. There were significant differences in MAVC140-80 kVp and MAVC100-40 keV between cholesterol and adenomatous polyps (P <0.05); these values were positive for cholesterol polyps and negative for adenomatous polyps. CONCLUSION: The unique energy spectrum information provided by DE-CT scans is helpful in differentiating between cholesterol and adenomatous polyps 1.0-2.0 cm in size.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pólipos / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Pólipos Adenomatosos / Neoplasias da Vesícula Biliar Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Radiol Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pólipos / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Pólipos Adenomatosos / Neoplasias da Vesícula Biliar Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Radiol Ano de publicação: 2021 Tipo de documento: Article