Your browser doesn't support javascript.
loading
Thyroid function in neonates conceived after hysterosalpingography with iodinated contrast.
van Welie, N; Roest, I; Portela, M; van Rijswijk, J; Koks, C; Lambalk, C B; Dreyer, K; Mol, B W J; Finken, M J J; Mijatovic, V.
Afiliação
  • van Welie N; Department of Reproductive Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1118, 1081 HV, Amsterdam, the Netherlands.
  • Roest I; Department of Reproductive Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1118, 1081 HV, Amsterdam, the Netherlands.
  • Portela M; Department of Obstetrics and Gynaecology, Máxima MC, De Run 4600, 5504 DB, Veldhoven, the Netherlands.
  • van Rijswijk J; Department of Reproductive Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1118, 1081 HV, Amsterdam, the Netherlands.
  • Koks C; Department of Reproductive Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1118, 1081 HV, Amsterdam, the Netherlands.
  • Lambalk CB; Department of Obstetrics and Gynaecology, Máxima MC, De Run 4600, 5504 DB, Veldhoven, the Netherlands.
  • Dreyer K; Department of Reproductive Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1118, 1081 HV, Amsterdam, the Netherlands.
  • Mol BWJ; Department of Reproductive Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1118, 1081 HV, Amsterdam, the Netherlands.
  • Finken MJJ; Department of Obstetrics and Gynaecology, Monash University, Scenic Blvd, Clayton, VIC 3800, Australia.
  • Mijatovic V; Department of Paediatric Endocrinology, Amsterdam UMC, Vrije Universiteit Amsterdam, Emma Children's Hospital, De Boelelaan 1118, 1081 HV, Amsterdam, the Netherlands.
Hum Reprod ; 35(5): 1159-1167, 2020 05 01.
Article em En | MEDLINE | ID: mdl-32427280
ABSTRACT
STUDY QUESTION Does exposure to preconceptional hysterosalpingography (HSG) with iodinated oil-based contrast affect neonatal thyroid function as compared to iodinated water-based contrast? SUMMARY ANSWER Preconceptional HSG with iodinated contrast did not influence the neonatal thyroid function. WHAT IS KNOWN ALREADY HSG is a commonly applied tubal patency test during fertility work-up in which either oil- or water-based contrast is used. Oil-based contrast contains more iodine compared to water-based contrast. A previous study in an East Asian population found an increased risk of congenital hypothyroidism (CH) in neonates whose mothers were exposed to high amounts of oil-based contrast during HSG. STUDY DESIGN, SIZE, DURATION This is a retrospective data analysis of the H2Oil study, a randomized controlled trial (RCT) comparing HSG with the use of oil- versus water-based contrast during fertility work-up. After an HSG with oil-based contrast, 214 women had an ongoing pregnancy within 6 months leading to a live birth compared to 155 women after HSG with water-based contrast. PARTICIPANTS/MATERIALS, SETTING,

METHODS:

Of the 369 women who had a live born infant, 208 consented to be approached for future research and 138 provided informed consent to collect data on the thyroid function tests of their offspring (n = 140). Thyroid function tests of these children were retrieved from the Dutch neonatal screening program, which includes the assessment of total thyroxine (T4) in all newborns, followed by thyroid-stimulating hormone only in those with a T4 level of ≤ -0.8 SD score. Furthermore, amount of contrast medium used and time between HSG and conception were compared between the two study groups. MAIN RESULTS AND THE ROLE OF CHANCE Data were collected from 140 neonates conceived after HSG with oil-based (n = 76) or water-based (n = 64) contrast. The median T4 concentration was 87.0 nmol/l [76.0-96.0] in the oil group and 90.0 nmol/l [78.0-106.0] in the water group (P = 0.13). None of the neonates had a positive screening result for CH.The median amount of contrast medium used was 9.0 ml [interquartile range (IQR), 6.0-11.8] in the oil-group and 10.0 ml [IQR, 7.5-14.0] in the water group (P = 0.43). No influence of the amount of contrast on the effect of contrast group on T4 concentrations was found (P-value for interaction, 0.37). LIMITATIONS, REASONS FOR CAUTION A relatively small sample size and possible attrition at follow-up are limitations of this study. Although our results suggest that the use of iodinated contrast media for HSG is safe for the offspring, the impact of a decrease in maternal thyroid function on offspring neurodevelopment could not be excluded, as data on maternal thyroid function after HSG and during conception were lacking. WIDER IMPLICATIONS OF THE

FINDINGS:

As HSG with oil-based contrast does not affect thyroid function of the offspring, there is no reason to withhold this contrast to infertile women undergoing HSG. Future studies should investigate whether HSG with iodinated contrast influences the periconceptional maternal thyroid function and, consequently, offspring neurodevelopment. STUDY FUNDING/COMPETING INTEREST(S) This study received no funding. The original H2Oil RCT was an investigator-initiated study that was funded by the two academic institutions (Academic Medical Center and VU University Medical Center) of the Amsterdam UMC. The funders had no role in study design, collection, analysis and intrepretation of the data. I.R. reports receiving travel fee from Guerbet. C.B.L. reports speakers fee from Ferring in the past and research grants from Ferring, Merck and Guerbet. K.D. reports receiving travel fee and speakers fee from Guerbet. B.W.M. is supported by a NHMRC Practitioner Fellowship (GNT1082548). B.W.M. reports consultancy for ObsEva, Merck KGaA and Guerbet and travel and research grants from Merck KGaA and Guerbet. V.M. reports receiving travel fee and speakers fee as well as research grants from Guerbet. The other authors do not report conflicts of interest. TRIAL REGISTRATION NUMBER Netherlands Trial Register NTR 7526 (Neonates born after the H2Oil study), NTR 3270 (original H2Oil study), www.trialregister.nl.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Histerossalpingografia / Meios de Contraste Limite: Child / Female / Humans / Newborn / Pregnancy País/Região como assunto: Europa Idioma: En Revista: Hum Reprod Assunto da revista: MEDICINA REPRODUTIVA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Histerossalpingografia / Meios de Contraste Limite: Child / Female / Humans / Newborn / Pregnancy País/Região como assunto: Europa Idioma: En Revista: Hum Reprod Assunto da revista: MEDICINA REPRODUTIVA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Holanda