Your browser doesn't support javascript.
loading
Numerical simulation of 222Rn profiling in an experimental chamber using CFD technique.
Agarwal, Tarun K; Sahoo, B K; Shetty, Trilochana; Gaware, J J; Kumara, Sudeep; Karunakara, N; Sapra, B K; Datta, D.
Afiliação
  • Agarwal TK; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India; Homi Bhabha National Institute, Anushaktinagar, Mumbai, 400094, India.
  • Sahoo BK; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.
  • Shetty T; Centre for Advanced Research in Environmental Radioactivity (CARER), Mangalore University, Mangalagangothri, Karnataka, 574199, India.
  • Gaware JJ; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.
  • Kumara S; Centre for Advanced Research in Environmental Radioactivity (CARER), Mangalore University, Mangalagangothri, Karnataka, 574199, India.
  • Karunakara N; Centre for Advanced Research in Environmental Radioactivity (CARER), Mangalore University, Mangalagangothri, Karnataka, 574199, India.
  • Sapra BK; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India. Electronic address: bsapra@barc.gov.in.
  • Datta D; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.
J Environ Radioact ; 220-221: 106298, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32560887
ABSTRACT
Measurement of indoor 222Rn concentration and interpretation of distribution patterns are important for inhalation dosimetry in occupational and residential areas. Experimental determination of 222Rn concentration distribution and estimation of inhalation doses depend on the underlying aspects such as calibration of the detectors, accuracy of the techniques etc. Therefore, 222Rn concentration distribution needs to be very well understood in a closed domain for the controlled studies. In the recent times, Computational fluid dynamics (CFD) technique has gained a lot of attention for the prediction and visualization of indoor 222Rn concentration profiles and their mixing ability in the domain. The present study aims to simulate the effect of forced mixing on the 222Rn concentration profile in a 22 m3 experimental chamber. This chamber is designed for carrying out the controlled experiments, calibration and inter-comparison studies of various types of 222Rn detectors. Effect of different parameters such as time, flow rates, fan-off and fan-on conditions have been studied on the transient response, extent of the air mixing patterns and subsequently on 222Rn concentration profile in the chamber. Further, Non uniformity index (NUI) is introduced as a measure of the uniformity of the distribution in the closed domain. NUI is estimated for different cases in order to efficiently interpret the effect of above mentioned parameters on 222Rn profile in the chamber. This study will be useful to represent the turbulent conditions in real indoor domains and occupational facilities as U-mines during calibration and inter-comparison exercises of different 222Rn detectors.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento de Radiação Idioma: En Revista: J Environ Radioact Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento de Radiação Idioma: En Revista: J Environ Radioact Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Índia